New in the library Presented by Jaadu Digital ↗
Free Business Profile Free tools
Industrial Dryers

Industrial Tunnel Dryers: Sizing Calculations, Airflow Rates & Belt Loading Guide

Jignesh S Panchal Updated 20 min read
Tunnel Dryers
Approx. 25 min read
On this page
  1. Tunnel dryer diagram: parts and their functions
  2. Tunnel Dryer Configurations: SI Metric & US Imperial Comparison
  3. What a tunnel dryer is, and what it is not
  4. How the air and the product move
  5. The air path
  6. The product path
  7. What the diagrams on this page show
  8. Tunnel dryer specifications: published values and open items
  9. Continuous or batch: which one your line actually needs
  10. Counter-flow, parallel-flow, cross-flow and through-flow compared
  11. Tray, belt or conveyor-in-tunnel: where each is the wrong choice
  12. Troubleshooting: symptom, likely cause, first action
  13. Applications: what tunnel dryers are used for
  14. Energy and running cost: what the published data supports
  15. Industrial Dryer Evaporation, Heat & Fuel Calculator
  16. Where a tunnel dryer is the wrong choice
  17. What to put in your RFQ
  18. Common selection mistakes
  19. Questions engineers ask
  20. What is the difference between a tunnel dryer and a tray dryer?
  21. How is residence time controlled in a tunnel dryer?
  22. Which airflow arrangement should I specify?
  23. How much energy does a tunnel dryer use?
  24. Why is my product dry on the outside and wet inside?
  25. Research reference
  26. Next step
  27. 🛠️ Recommended Engineering Guides & Tools
  28. Sources and further reading
  29. More on Industrial Dryers

A tunnel dryer is a convective dryer built as a long enclosed chamber. Product travels through it on trolleys, trays, belts or hanging frames, from a wet inlet at one end to a dry outlet at the other, while a blower moves air across a heater and over or through the product. The deciding variable is the drying curve of your material: how fast internal moisture can reach the surface before the surface sets over. The main configurations are tray-on-trolley, conveyor-in-tunnel and multi-pass belt.

Tunnel dryer diagram: parts and their functions

Tunnel dryer diagram with labelled parts: entry door, trucks with trays, insulated tunnel, rails, fresh-air inlet, fan, air heater, hot air flow, exhaust stack and exit door
Tunnel dryer diagram: a truck-and-tray tunnel dryer in side section with counter-current airflow. In a co-current tunnel the hot air enters at the wet end instead.
No.PartWhat it does
1Entry doorTrucks of wet product enter here.
2Trucks with traysThe product is spread in thin layers on trays stacked on wheeled trucks.
3Insulated tunnelLong enclosure that holds the heat around the product.
4RailsGuide the trucks. Each new truck pushed in moves the whole row one place forward.
5Fresh-air inletDraws in the air that will carry the moisture away.
6Circulation fanDrives the air through the heater and along the tunnel.
7Air heaterRaises the air temperature. It can be a steam coil, a burner or an electric heater.
8Hot air flowPasses over the trays and picks up moisture. Shown counter-current: the hottest, driest air meets the driest product.
9Exhaust stackMoist air leaves at the wet end. Part of it is often recirculated to save energy.
10Exit doorTrucks of dried product leave here.

Download this diagram (SVG)Schematic for learning. Real machines vary by maker and duty.

This page is for process, plant and purchase engineers comparing a tunnel dryer with other dryer types, or trying to fix one that is already running. Published measured data is cited with its scope. Where a number could not be sourced, the cell says so instead of carrying an estimate.

SI Metric + US Imperial · Engineering Comparison

Tunnel Dryer Configurations: SI Metric & US Imperial Comparison

ISO 13579 / EN 1539 / NFPA 86 / ISO 13577

Compare airflow arrangement, face velocity, operating temperature, specific evaporation rate, and thermal energy demand across industrial tunnel dryers.

ConfigurationAir Velocity (m/s | fpm)Operating Temp (°C | °F)Evaporation Rate (kg/m²·h | lb/ft²·h)Specific Heat (kJ/kg | BTU/lb H2O evap.)Residence Time
Counter-Flow Tunnel1.5–4.0 m/s (295–790 fpm)60–140 °C (140–284 °F)2.5–8.0 kg/m²·h (0.5–1.6 lb/ft²·h)3,600–4,800 kJ/kg (1,550–2,065 BTU/lb H2O evap.)2–12 h (tray trucks, ceramics)
Co-Current Tunnel2.0–5.5 m/s (395–1,080 fpm)80–220 °C (176–428 °F)4.0–12.0 kg/m²·h (0.8–2.5 lb/ft²·h)3,400–4,500 kJ/kg (1,460–1,935 BTU/lb H2O evap.)1–6 h (heat-sensitive foods)
Center-Exhaust Tunnel2.0–4.5 m/s (395–885 fpm)70–160 °C (158–320 °F)3.5–10.0 kg/m²·h (0.7–2.0 lb/ft²·h)3,200–4,100 kJ/kg (1,375–1,765 BTU/lb H2O evap.)1.5–8 h (fruit, vegetables)
Multi-Stage Band Dryer1.0–3.5 m/s (195–690 fpm)65–180 °C (149–356 °F)8.0–25.0 kg/m²·h (1.6–5.1 lb/ft²·h)3,100–3,900 kJ/kg (1,330–1,675 BTU/lb H2O evap.)15–90 min (continuous pellets)
Standards: ISO 13579 / EN 1539 / NFPA 86 / ISO 13577Run interactive sizing calculator ↓

What a tunnel dryer is, and what it is not

A tunnel dryer is a chamber, not a heating technology. The chamber gives you a long product path in a compact footprint, and that path is divided into zones with independent air conditions. Three things define the machine:

Advertisement
  • The carrier. Trays on trolleys, a mesh or slat belt, a roller bed, or hanging frames. The carrier decides bed depth, product turning and how the load enters.
  • The air path. Air is drawn in, moved by a blower, heated (direct-fired, steam coil, thermal oil, electric, or with infrared, radio-frequency or microwave sections added inside the tunnel), then passed over or through the product and exhausted.
  • The zone profile. Temperature, humidity and air velocity set independently along the length, so the harsh end matches the wet product and the mild end matches the dry product.

It is not a bigger tray dryer in the sense that matters. A tray dryer holds one batch under one condition. A tunnel dryer exposes the same batch to a sequence of conditions, which is why it can dry materials that case-harden or crack in a cabinet.

It is also not automatically a continuous machine. Trolley-indexed tunnels run semi-continuously, with the trolley step interval as the throughput control. The measured cassava tunnel described below ran that way.

How the air and the product move

This section is written so it can be followed without opening the images, because the figures may not render on a phone or may be replaced during a redesign.

The air path

Fresh air enters near one end of the tunnel. A blower pulls or pushes it through the heater. The heated air then travels the length of the chamber and leaves through exhaust outlets, usually at the top or at the far end. A recirculation line takes part of the used air, mixes it with fresh air through a damper, and sends it back through the heater. Recirculation cuts the heat needed to bring incoming air up to temperature, but it also recycles the moisture and, where the product is dusty, the solids.

The product path

Wet product enters at one end on the carrier and moves step by step or continuously toward the discharge end. In the field-measured tunnel reviewed by Precoppe and others (Journal of Food Process Engineering, 2017), trolleys were indexed forward manually every 50 minutes, counter-current to the air flow, and a loaded trolley replaced the one that left. Residence time in that class of machine is therefore set by the index interval, and in a belt machine by belt speed.

The two paths can run in the same direction, opposite directions, or at right angles. That single choice changes the moisture profile, the energy figure and the risk of surface damage. It is compared below.

Advertisement

What the diagrams on this page show

Two figures are on this page, and both are diagrams rather than photographs.

  • The first is a cross-section of a tray tunnel with a recirculation loop. Labels read: exhaust air, recirculated damper, fresh air inlet, recirculated air, heaters, blower, side entrance for wet trays, side exit for dry trays. Air enters at the top near the dry end, is pushed by the blower through the heaters, passes over the tray stack, and leaves through the exhaust at the opposite top corner.
  • The second is an isometric arrangement drawing plus a block flow sheet. The drawing shows the tunnel main body on a steel structure with an automatic opening and closing door, an air blower on the roof, an operation panel, an entrance conveyor, a trolley feed conveyor, a lift and loader at the inlet end, a lift and extractor at the outlet end, an exit conveyor and a lower conveyor for trolley return. The flow sheet runs: drying materials, sorting or sizing or alignment machine, feeder, lift, loader, cushion loader into the tunnel dryer, then lift, extractor, tray or product separator, dried product, with a tray return device and a trolley return device closing the loop.
Cross-section of a tray tunnel dryer with recirculation loop, fresh air inlet, heaters, blower and exhaust
Figure 1 – cross-section of a tray tunnel with a recirculation loop: fresh air inlet, heaters, blower, recirculated damper, exhaust, wet-tray entrance and dry-tray exit.
Isometric arrangement of a tunnel dryer with entrance conveyor, lift and loader, roof blower and exit conveyor, plus a block flow sheet
Figure 2 – isometric arrangement and block flow sheet: entrance conveyor, lift and loader, tunnel body with roof blower, extractor and exit conveyor, with trolley and tray return.

Read together, the two figures show the two halves of the machine that suppliers quote separately: the drying chamber with its air circuit, and the material handling that feeds and empties it. The handling package is usually where a tunnel dryer stops matching a plant layout.

Tunnel dryer specifications: published values and open items

Units are degrees Celsius (deg C), kilograms per hour (kg/h), metres per second (m/s) and megajoules per kilogram of water evaporated (MJ/kg). “Measured” means a machine that was instrumented and reported in a peer-reviewed paper. “Vendor indicative” means a manufacturer’s published range, not a guarantee. There is no such thing as a standard tunnel dryer specification table; the honest column is the last one.

ParameterPublished valueUnitScope and sourceHow to close it
Chamber length5.0mMeasured small wood-fired cassava tray tunnel (Precoppe et al. 2017)Compare with supplier general-arrangement drawing for your duty
Chamber cross-section1.8 high x 0.9 widemSame measured unitAsk for free air gap above and below trays
Effective belt length, single pass4 to 40mVendor indicative, Lozzar Process belt dryer page, accessed 2026-10-28Confirm against the supplier’s sizing calculation
Total tunnel length, ceramics or brickNot publishedmOne Indian vendor publishes 5 m pilot units to over 150 m brick and ceramic dryers (Kerone page, accessed 2026-10-28); no independent source foundTwo quotations sized on your water load
Independently controlled zonesNot publishedcountVendor statements range from two or three zones for robust products to five or more for food items and pharmaceutical granules (Kerone, Lozzar)Set zones where your drying rate curve changes, not from a catalogue
Residence time, trolley index50min per stepMeasured unit, manual indexingConfirm the drive can hold the step you need
Residence time, total transitabout 300 (arithmetic: 6 trolleys x 50 min)minDerived from the same paper’s stated valuesRecompute for your carrier pitch and tunnel length
Belt speed as residence control0.01 to 0.3m/minVendor indicative (Lozzar)Confirm with the supplier’s drive turndown
Inlet air temperature125.5 +/- 12.9deg CMeasured cassava tunnel, wood-fired shell-and-tube heat exchangerCap it at your product’s maximum allowable temperature
Exhaust air temperature73.4 +/- 7.2deg CSame measured unitCheck it stays above the dew point margin you specify
Air temperature range, belt machines40 to 250deg CVendor indicative; the same table gives 40 to 120 for food and pharma, 80 to 150 for biomass chips, 100 to 200 for technical pellets, and caps it by belt material (polyester 200, stainless mesh 400)Confirm against your product’s browning, case-hardening or softening limits
Air velocity over the product, tray tunnelNot publishedm/sThe measured study reports air mass flow, not velocity at tray heightAsk for a velocity traverse at top, middle and bottom tray rows
Air velocity through the bed, through-flow0.5 to 3.0m/sVendor indicative (Lozzar), stated to be kept below particle entrainment velocityConfirm with your particle size and bulk density
Air mass flow450.6 measured, 195.7 calculated minimumkg dry air/hMeasured cassava unitAsk for both figures in every offer
Bed or layer depth20 to 150 (vendor indicative); 50 to 100 (measured sludge belt machine)mmLozzar belt dryer page; ANDRITZ BDS belt dryer pageShallower bed for uniform drying, deeper for throughput
Moisture in47.7 +/- 2.7 wet basisper centMeasured cassava granulate after pressingYour own lab value, on the same basis
Moisture out14.0 +/- 5.9 wet basisper centSame unit; a storage target below 14 per cent wet basis for cassava flour is cited in the paperSpecify the target and the acceptable spread
Feed capacity13.2 +/- 0.0 wetkg/hMeasured cassava unitDo not size on this; size on water evaporated
Dried output8.0 +/- 0.1kg/hSame measured unitCheck turndown at minimum output
Specific energy consumption8.5 +/- 1.0 measured; 5.5 to 6.0 literature rangeMJ per kg waterMeasured unit had 20 mm plywood walls and no automatic control; the literature range is cited to Mujumdar (2014) inside the same paperConfirm for your machine class, insulation and heat recovery
Theoretical floor for evaporationabout 2.5MJ per kg waterCited to Strumillo et al. (2014) inside the same paperUse it as a reference line, not a target
Energy efficiency28.7 +/- 3.2 measured; 20 to 60 typical for convective dryersper centMeasured unit; typical range cited to Strumillo et al. (2014)Ask for a guaranteed figure at your duty point
Blower electrical power0.41 +/- 0.01 (1.1 kW motor)kWMeasured unitConfirm fan law assumptions before VFD claims
Wall insulation20 (measured small unit)mmPlywood with aluminium facing; industrial units use mineral wool or PUF panels at thicknesses that need confirmingAsk for panel thickness, core conductivity and heat loss per square metre

Continuous or batch: which one your line actually needs

A tunnel is chosen for continuous or semi-continuous duty: one feed point, one discharge point, a fixed profile along the length, and throughput set by carrier speed. Batch drying stays the better answer when the product mix changes weekly, when a single batch must be tracked, or when volume does not justify a handling system at both ends.

The published comparison of batch and continuous convective systems is blunt about the trade. In grain drying, high-temperature batch systems are valued for capacity and simplicity, but their product quality and energy efficiency are described as marginal, and bed depth has to be limited to 0.6 to 1.2 m to stop the bottom layer being over-dried (FAO, Bakker-Arkema). Continuous machines trade that flexibility for a repeatable profile.

  • Choose continuous or indexed tunnel when one product runs for long campaigns, the moisture target is tight, and the line is fed from a washer, press or extruder without a buffer.
  • Choose batch (tray, cabinet, trolley-in-room) when you change materials often, need clean validation between products, or cannot feed a tunnel steadily.
  • Choose a hybrid only when a supplier can show you the changeover time in writing, not verbally.

Counter-flow, parallel-flow, cross-flow and through-flow compared

Purdue University’s agricultural engineering material classifies continuous-flow dryers by the relative direction of product and air, and names cross-flow and mixed-flow as the common high-capacity designs; in a cross-flow machine the product column moves one way and the air crosses it at right angles, while a mixed-flow path is a combination of cross-, co-current and counter-flow movement inside the chamber. Tunnel dryer suppliers describe their air arrangements as counterflow, parallel flow or combined flow. Through-flow is a different idea: the air goes through the product layer instead of over it.

See it in 3D

Interactive 3D Spray Dryer with Cyclone Co-current spray drying: a rotary atomizer sprays liquid feed into hot air, droplets dry as they fall, and a cyclone recovers the fine powder. Drag to rotate · scroll or pinch to zoom · tap a part to learn what it does
Size it: Industrial Dryer Evaporation, Heat & Fuel Calculator →
Air arrangementHow air meets productWhere it helpsWhere it is the wrong choice
Counter-flow (co-current in reverse: air opposite to product)Hottest, driest air meets the driest product near the exit; coolest, most humid air meets the wet product at the inletMaterials that crust or crack if the wet surface is hit with harsh air; the measured cassava tunnel ran the trolleys counter-current to the airProducts that cannot tolerate hot dry air at the end of the path, or that must reach a very low final moisture quickly; the wettest air sits where the product still has most water to give up
Parallel-flow (co-current)Air and product travel the same way; wettest product meets the hottest, driest airFast initial moisture removal on robust products with abundant surface moistureStarchy, sugary or soluble-rich surfaces that set over: vendor guidance names surface hardening and case-hardening as the risk in this arrangement, and the driest product then meets the coolest, most humid air at discharge
Cross-flowAir crosses the product path at right angles, typically over the top of a tray stack as in the diagram on this pageSimple ducting and easy retrofit of an existing tray tunnel; the standard arrangement in most tray-indexed machinesWide beds and deep stacks, because the air cools and loads with moisture as it crosses, so the far rows see milder conditions; expect a moisture gradient to be tested, not assumed
Mixed or combined flow (zoned)Different arrangements in different zones along the tunnelProducts with a real drying curve: aggressive first zone, gentler middle to avoid case-hardening, low-temperature conditioning or cooling at the end (the zone strategy published for belt machines)Where you have no drying-curve data and no one to tune five zones; extra dampers and controls are extra failure points
Through-flow (through the bed)Air is pulled or pushed through the product layer on a perforated beltGranules, pellets, extrudates, slices and leaves that form a permeable bed; better air-to-solids contact and more uniform drying than flow over the top, per vendor design guidanceFine powders and light particles: they blind the belt or are blown through it. Vendor guidance puts a stable-bed minimum near 3 mm particle size and keeps velocity below entrainment velocity

Tray, belt or conveyor-in-tunnel: where each is the wrong choice

CarrierWhat it suitsWrong choice when
Trays on trolleys, indexed through the tunnelSlices, whole pieces, products that must stay in place and be inspected; low capital and maintenance cost is the reason this type is used at small scale (stated in the measured study, citing Mujumdar 2008 and Levy and Borde 2014); any product that fits on a trayYou need turnkey throughput above a few hundred kilograms per hour, you cannot staff the indexing, or tray loading and unloading dominates labour
Mesh or perforated belt (single or multi-pass)Granules, pellets, chips, slices, leaves; continuous feed and discharge; multi-pass designs fold 2 to 5 belt levels into a shorter chamberProduct is sticky, finer than about 3 mm, or soft enough to mark; mesh cleaning between products is a validation burden
Slat or rod conveyor inside the tunnelContainers, closures, bottles, vials, formed bodies and packages that must keep orientation; the suitability of a carrier depends on the product and transfer arrangementSmall loose product that falls between slats, or items that tip; slat transfer points become the jam and carryover problem
Hanging frames or chainsCoated or painted parts, timber stock, items dried by air plus radiationAnything that sags, drips or deforms under its own weight while warm

Troubleshooting: symptom, likely cause, first action

These symptoms can have several causes. Follow site safety procedures and involve the equipment supplier or qualified process engineer before changing temperature, airflow, speed, dampers or exhaust arrangements. The questions below help organize an investigation; they are not operating setpoints.

Advertisement
SymptomQuestions to investigate
Dry exterior and wet interiorIs the moisture test representative of both surface and interior? What were the product, loading and air conditions? Discuss possible case hardening and a product-specific trial with the supplier.
Uneven drying or crackingAre feed properties, loading and measured conditions consistent across the carrier? Document where the difference occurs and ask how the sampling plan and operating profile should be evaluated.
Over-dried productAre the moisture test, residence-time records and temperature measurements consistent with the agreed product specification? Ask the supplier to review the complete process profile.
Carryover, dust or depositsDocument where the material appears and ask the responsible safety and engineering teams to assess the product, air path and dust hazards before changing operation or recirculation.
Condensation or wet spotsRecord when and where it occurs. Ask the supplier to review measured air conditions, moisture load, cold surfaces and the equipment’s permitted operating range.
High energy useRecord product throughput, inlet and outlet moisture, fuel and electrical use for the same period. Ask an engineer to define the measurement boundary before comparing machines or proposals.

Applications: what tunnel dryers are used for

Supplier application lists for tunnel dryers cover dehydrated fruits, vegetables, spices, pasta and crackers, pharmaceutical granules and herbal powders, chemicals, pigments and catalysts, ceramics, bricks and tiles, timber, textiles, and packaging components such as caps, vials and containers (Kerone and Lozzar pages, vendor statements). The measured industrial case in the sources behind this page is cassava granulate dried to a storage moisture below 14 per cent wet basis.

Treat an application list as a starting point, then ask two questions:

  • Has this supplier dried your material, or a material with the same particle size, bound-water behaviour and maximum allowable temperature?
  • Can they give a contact who will answer the phone about moisture spread and downtime, not just throughput?

Where a tunnel dryer competes with another machine on your product, the honest comparison is: fluid bed dryers for free-flowing granules, spray dryers for liquids and slurries, rotary dryers for high bulk tonnages, paddle and spin-flash dryers for pastes and sludges, freeze or vacuum dryers for heat-sensitive high-value products, and kilns where the piece must be fired rather than dried.

Energy and running cost: what the published data supports

No savings percentage is quoted on this page, because none of the sources reviewed supports one for a machine you have not sized. What the sources do support is a measured reference machine, and a method you can run on your own numbers.

From the field-measured cassava tunnel (Precoppe et al. 2017), with its scope attached: a 5.0 m chamber, wood-fired heat exchanger, 20 mm plywood walls, no automatic control, inlet air at 125.5 deg C, exhaust at 73.4 deg C, 13.2 kg/h wet feed at 47.7 per cent wet basis leaving 8.0 kg/h at 14.0 per cent wet basis. It consumed 9.0 kg/h of wood shavings at 22.40 MJ/kg, gave a specific energy consumption of 8.5 MJ per kg of water evaporated, and an energy efficiency of 28.7 per cent. Heat left the machine mainly through the exhaust (50.5 per cent) and secondarily through the walls (11.5 per cent).

Interactive Plant Sizing · SI Metric & US Imperial

Industrial Dryer Evaporation, Heat & Fuel Calculator

Water evaporation, product output, heat load and fuel or steam consumption for spray, rotary, flash, fluid-bed and paddle dryers.

Free engineering tool Formula, worked example and FAQs below · results update as you type
%
%
kJ/kg
Latent heat + sensible heat ≈ 2400–2700 kJ/kg
%
Spray 40–60 % · rotary 50–70 % · paddle (indirect) 70–85 %
kJ/kg

Results

Water evaporated
— kg/h
Dried product
— kg/h
Bone-dry solids
— kg/h
Heat input required
—
Fuel / steam consumption
— kg/h
Specific energy
— kJ/kg water

Results are engineering estimates for preliminary design. Verify critical values with codes, vendor data or a qualified engineer.

Advertisement

Worked example, all inputs visible, arithmetic on the paper’s own published values, so you can check every line:

  • Dry solids in feed = 13.2 kg/h x (1 – 0.477) = 6.90 kg/h.
  • Dried product at 14.0 per cent wet basis = 6.90 / (1 – 0.14) = 8.03 kg/h, which matches the reported 8.0 kg/h.
  • Water evaporated = 13.2 – 8.03 = 5.17 kg/h.
  • Heat added to the air = 5.17 kg/h x 8.5 MJ/kg = 43.9 MJ/h, which equals 12.2 kW and matches the reported heat rate.
  • Fuel energy input = 9.0 kg/h x 22.40 MJ/kg = 201.6 MJ/h.
  • The ratio of estimated air-side heat to estimated fuel energy is 43.9 / 201.6 = 21.8 per cent. This calculation uses the listed averages and is not the study’s separately defined thermal-efficiency figure.
  • Ideal heat of evaporation, using the 2.5 MJ/kg reference cited in the paper, is 5.17 x 2.5 = 12.9 MJ/h, so the machine used about 3.4 times the thermodynamic minimum at the air side.

Read that list as a diagnosis template, not a benchmark for an insulated, automatically controlled industrial machine. The same paper cites a literature range of 5.5 to 6.0 MJ per kg water for tunnel dryers, and 20 to 60 per cent energy efficiency for convective dryers generally. Differences between published figures can reflect equipment, product, measurement boundaries and operating conditions; they do not establish why any particular machine differs.

For the studied cassava dryer, the authors calculated a minimum air mass flow of 195.7 kg dry air/h, compared with a measured average of 450.6 kg dry air/h. This was a model calculation for that particular unit, not a measured operating limit or a recommended adjustment for another dryer. Consult the original study and assess the actual product, equipment and safety requirements before changing airflow.

Where a tunnel dryer is the wrong choice

  • Fine powders and low-density flakes on a through-flow or high-velocity machine: they blind the belt, blow off, or end up in the exhaust.
  • Slurries, solutions and pumpable feeds: they need a spray, drum or flash dryer, not a tunnel.
  • Sticky pastes and cakes: they smear on a belt and load on a tray; paddle or spin-flash dryers exist for that behaviour.
  • Very heat-sensitive, high-value products: vacuum or freeze drying keeps oxygen and temperature down where a convective tunnel cannot.
  • Frequent product changeover with strict residue limits: a long tunnel is a long clean, and the cleaning time is rarely quoted.
  • Low throughput: the handling system at both ends costs more than the chamber and sits idle.

What to put in your RFQ

  • Material as received: particle size distribution, bulk density, initial moisture on a stated basis, maximum allowable product temperature, and the behaviour of the surface when it dries fast.
  • Target moisture, plus the acceptable spread and the test method you will use at handover.
  • Water evaporation rate in kg/h, calculated from your moisture removal, not feed rate.
  • Required zone count and the profile you expect, with the right for the supplier to counter-propose in writing.
  • Air side: inlet and exhaust temperature, air mass flow, minimum air flow before condensation risk, and velocity at product height.
  • Utilities available: steam pressure, thermal oil, fuel, electrical load, ambient design conditions, and where the exhaust may go.
  • Emission and safety scope: dust capture, exhaust route, and the explosion-risk review for your dust, with the applicable requirement confirmed for your market rather than assumed.
  • Handling: infeed and discharge equipment, carrier pitch, indexing method, spares, and access for cleaning.
  • Commissioning: a trial on your own material, with moisture spread and specific energy measured, not promised.
  • Performance figures to be guaranteed at the duty point, and the test that proves them.

Common selection mistakes

  • Sizing on feed rate instead of water evaporated. The machine is bought by the kilogram of water.
  • Copying a temperature profile from a similar plant. Similar product, different bound water, different result.
  • Ignoring the maximum allowable product temperature until the first batch is ruined.
  • Accepting a catalogue zone count instead of setting zones where the drying rate changes.
  • Treating airflow as fixed. It is the parameter that decides exhaust loss, case hardening and condensation at the same time.
  • No trial on the customer’s own material, so the moisture spread is discovered during the first production week.
  • Quoting the chamber and forgetting the lift, loader, extractor and return conveyors that the arrangement drawing shows.

Free tools for this topic: Dryer selection tool · Dryer evaporation, heat and fuel calculator · all free engineering tools

Questions engineers ask

What is the difference between a tunnel dryer and a tray dryer?

A tray dryer is a batch cabinet: trays stay in one air condition until the batch is done. A tunnel dryer puts those trays on trolleys or a belt and moves them through a sequence of air conditions, which converts one condition into a profile and makes the machine continuous or semi-continuous. The measured tunnel in the sources is described as a convective dryer where products sit on trays stacked on trolleys that move along the chamber.

How is residence time controlled in a tunnel dryer?

By the carrier. In a trolley-indexed tunnel it is the interval between index steps, and the study reviewed here states that residence time is controlled by changing that interval. In a belt tunnel it is belt speed, with vendor indicative speeds of 0.01 to 0.3 m/min, and multi-pass belts add residence time without adding chamber length.

Which airflow arrangement should I specify?

The one that matches your material’s drying curve. Counter-flow protects the wet surface and puts the harshest air on the driest product. Parallel-flow removes surface water fastest and risks setting the surface on starchy or sugary materials. Cross-flow is the simplest over-the-tray path and needs testing for a moisture gradient across the bed. Through-flow gives direct air-to-particle contact but only works with a permeable bed. Purdue’s classification and the supplier arrangements above are the vocabulary; your trial data decides.

How much energy does a tunnel dryer use?

Published measured data gives 8.5 MJ per kg of water evaporated and 28.7 per cent energy efficiency for a small, poorly insulated, manually controlled unit, against a literature range of 5.5 to 6.0 MJ per kg for tunnel dryers and a thermodynamic floor near 2.5 MJ per kg. Any figure quoted for your machine should be tied to your moisture load, insulation and heat recovery, and guaranteed at a duty point.

Why is my product dry on the outside and wet inside?

Case hardening is one possible explanation, but appearance alone does not establish the cause. Document the moisture test and process conditions, then ask the supplier or a qualified process specialist to assess the product and a suitable trial before changing the dryer settings.

Research reference

Precoppe and colleagues, Tunnel Dryer and Pneumatic Dryer Performance Evaluation to Improve Small-Scale Cassava Processing in Tanzania, Journal of Food Process Engineering, 2017, e12274. The measurements describe the small cassava-processing units studied; they are not universal equipment specifications.

Next step

Before asking for a quotation, get three numbers on your own material: initial and target moisture on the same basis, the water evaporation rate in kg/h that follows from them, and the maximum product temperature the material tolerates. Those three decide the tunnel length, the zone count and the air side, and they are what a competent supplier will ask for first.

Use the equipment quotation comparison guide to record open questions and compare the scope of offers. Ask the supplier or a qualified engineer to verify the proposed duty and guarantees.

Sources and further reading

For standards, data and independent guidance on this topic, see NFPA (combustible dust and fire safety standards), US Chemical Safety Board (dust explosion investigation reports) and IECEx (hazardous area equipment certification). Always check the current edition and your site conditions before applying any figure.

Free tool for this topic

Industrial Dryer Evaporation, Heat & Fuel CalculatorWater evaporation, product output, heat load and fuel or steam consumption for spray, rotary, flash, fluid-bed and paddle dryers.
Open calculator

Continue learning

More on Industrial Dryers

View all →
Sponsored
Jignesh S Panchal
Technical Editorial Author Verified Editor

Jignesh S Panchal

Founder — Jaadu Digital & Musafir Infotech · 9+ Years in Industrial B2B

Jignesh S Panchal is the founder of Jaadu Digital and Musafir Infotech, and the publisher behind EngiTech. With over 9 years of hands-on experience in industrial marketing and B2B growth, he works closely with machinery OEMs, process equipment manufacturers, and industrial service providers across thermal processing, fluid handling, automation, packaging, and plant reliability. Combining deep practical knowledge of industrial manufacturing with how technical buyers actually evaluate equipment, he built EngiTech to give plant engineers and procurement teams reliable sizing tools, fault diagnostics, and verified B2B supplier discovery.

Your saved guides

Saved only in this browser. No account required.