Calculate IEC 60534 liquid flow coefficient Cv and Kv, differential pressure drop, rated valve Cv at 75 % opening and high-ΔP cavitation risk.
Results
- Required Cv (US)
- Cv
- Required Kv (metric)
- Kv
- Valve pressure drop (ΔP)
- Rated valve Cv (at 75 % capacity)
- Cv
Results are engineering estimates for preliminary design. Verify critical values with codes, vendor data or a qualified engineer.
Formula used
IEC 60534 liquid sizing: Kv = Q [m³/h] × √(SG ÷ ΔP [bar]). Imperial coefficient: Cv = 1.156 × Kv = Q [US gpm] × √(SG ÷ ΔP [psi]).
Select a rated valve Cv such that normal flow operates around 60–80 % of rated capacity. High ΔP/P1 (> 0.5) signals possible cavitation or flashing.
How to use this calculator
- Enter required normal/max liquid flow rate.
- Enter absolute upstream and downstream pressures (gauge + 1.013 bar).
- Enter fluid specific gravity relative to water.
- Select a standard valve trim whose rated Cv is roughly 1.25–1.4× the required Cv.
Worked example
Water (SG = 1) at 40 m³/h with P1 = 6 bar a and P2 = 4.5 bar a (ΔP = 1.5 bar) requires Kv = 32.66 (Cv = 37.76). Choosing a rated valve near Cv ≈ 50 keeps normal opening in the linear control band.
Frequently asked questions
Why not size a control valve the same size as the line pipe?
Oversizing forces the plug to throttle near the seat (< 20 % lift), causing poor loop stability, hunting and rapid seat wire-drawing. Control valves are often one size smaller than the line.
What is the conversion between Cv and Kv?
Cv equals 1.156 × Kv (or Kv = 0.865 × Cv). Cv uses US gpm and 1 psi drop; Kv uses m³/h and 1 bar drop.
How do I prevent cavitation in a high-ΔP liquid valve?
Use anti-cavitation multi-stage trim, orient flow-to-close if recommended, increase downstream backpressure or split the pressure drop across two valves or an orifice plate.