Calculate volumetric flow, mass flow, beta ratio (d/D) and permanent pressure loss across a concentric orifice plate or Venturi tube per ISO 5167.
Results
- Volumetric flow
- Mass flow
- Beta ratio (β = d / D)
- Permanent pressure loss
Results are engineering estimates for preliminary design. Verify critical values with codes, vendor data or a qualified engineer.
Formula used
ISO 5167 incompressible flow: Q = (Cd × Ao ÷ √(1 − β⁴)) × √(2·ΔP ÷ ρ), where β = d ÷ D and Ao = π·d² ÷ 4.
Mass flow ṁ = Q × ρ. Keep β between 0.20 and 0.75 for reliable ISO 5167 accuracy.
How to use this calculator
- Enter pipe inside diameter D and orifice bore d.
- Enter the differential pressure ΔP read by the DP transmitter.
- Enter operating fluid density and discharge coefficient (0.61 for sharp-edged orifice, 0.98 for Venturi).
- Verify β lies between 0.20 and 0.75 and check permanent pressure loss against pump head.
Worked example
Water (1000 kg/m³) through a 60 mm orifice in a 100 mm bore pipe (β = 0.60, Cd = 0.61) at ΔP = 25 kPa gives 46.8 m³/h (13.0 kg/s) with 16.2 kPa permanent pressure loss.
Frequently asked questions
Why is flow proportional to the square root of ΔP?
Differential pressure varies with kinetic energy (½ρv²), so doubling the flow quadruples ΔP. DP transmitters apply square-root extraction to output a linear 4–20 mA flow signal.
When is a Venturi tube better than an orifice plate?
Venturi tubes recover 85–90 % of the differential pressure (far lower permanent energy loss) and resist plugging on slurries or large cooling-water headers.
How much straight pipe run does an orifice plate need?
Depending on β and upstream fittings, ISO 5167 typically requires 10–40 pipe diameters of straight run upstream and 4–7 diameters downstream.