Orifice Plate & Venturi DP Flow Calculator

No sign-up · calculates in your browser

Calculate volumetric flow, mass flow, beta ratio (d/D) and permanent pressure loss across a concentric orifice plate or Venturi tube per ISO 5167.

Free engineering tool Formula, worked example and FAQs below · results update as you type
Concentric orifice ≈ 0.60–0.62; Venturi ≈ 0.98

Results

Volumetric flow
—
Mass flow
—
Beta ratio (β = d / D)
—
Permanent pressure loss
—

Results are engineering estimates for preliminary design. Verify critical values with codes, vendor data or a qualified engineer.

Advertisement

Formula used

ISO 5167 incompressible flow: Q = (Cd × Ao ÷ √(1 − β⁴)) × √(2·ΔP ÷ ρ), where β = d ÷ D and Ao = π·d² ÷ 4.

Mass flow ṁ = Q × ρ. Keep β between 0.20 and 0.75 for reliable ISO 5167 accuracy.

How to use this calculator

  1. Enter pipe inside diameter D and orifice bore d.
  2. Enter the differential pressure ΔP read by the DP transmitter.
  3. Enter operating fluid density and discharge coefficient (0.61 for sharp-edged orifice, 0.98 for Venturi).
  4. Verify β lies between 0.20 and 0.75 and check permanent pressure loss against pump head.

Worked example

Water (1000 kg/m³) through a 60 mm orifice in a 100 mm bore pipe (β = 0.60, Cd = 0.61) at ΔP = 25 kPa gives 46.8 m³/h (13.0 kg/s) with 16.2 kPa permanent pressure loss.

Frequently asked questions

Why is flow proportional to the square root of ΔP?

Differential pressure varies with kinetic energy (½ρv²), so doubling the flow quadruples ΔP. DP transmitters apply square-root extraction to output a linear 4–20 mA flow signal.

When is a Venturi tube better than an orifice plate?

Venturi tubes recover 85–90 % of the differential pressure (far lower permanent energy loss) and resist plugging on slurries or large cooling-water headers.

How much straight pipe run does an orifice plate need?

Depending on β and upstream fittings, ISO 5167 typically requires 10–40 pipe diameters of straight run upstream and 4–7 diameters downstream.