New in the library Presented by Jaadu Digital ↗
Free tools

Free engineering tool · verified formulas

Cyclone Dust Collector Cut-Size (d50) & Velocity Calculator

No sign-up · calculates in your browser

Calculate Stairmand high-efficiency cyclone inlet velocity, Lapple 50 % cut-point particle diameter (d50 in µm) and estimated gas pressure drop.

Free engineering tool Formula, worked example and FAQs below · results update as you type
Ambient air ≈ 18.5 µPa·s; 150 °C flue gas ≈ 24 µPa·s

Results

Inlet velocity
—
Cut-point diameter (d50)
—
Estimated pressure drop
—

Results are engineering estimates for preliminary design. Verify critical values with codes, vendor data or a qualified engineer.

Advertisement

Formula used

Stairmand high-efficiency proportions: inlet area a × b = (0.5 Dc) × (0.2 Dc) = 0.1 Dc², effective turns Ne = 5.

Lapple cut-size: d50 = √(9·μ·b ÷ (2·π·Ne·vin·(ρp − ρg))). Pressure drop ΔP ≈ 6.4 × ½·ρg·vin².

How to use this calculator

  1. Enter actual gas volumetric flow at operating temperature and pressure.
  2. Enter cyclone cylinder body diameter Dc.
  3. Enter gas viscosity, gas density and particle density.
  4. Aim for 15–22 m/s inlet velocity; follow with a <a href="/bag-filter-sizing-calculator/">Bag Filter</a> for sub-5 µm emissions compliance.

Worked example

At 5,000 Am³/h in an 800 mm Stairmand cyclone (2500 kg/m³ dust, air at 20 °C), inlet velocity is 21.7 m/s, cut-size d50 ≈ 4.3 µm and pressure loss ≈ 1,808 Pa (184 mmH2O).

Frequently asked questions

What does a cyclone d50 cut-size of 5 µm mean?

Particles of 5 µm aerodynamic size have a 50 % chance of being collected; larger particles are captured at progressively higher efficiency (80–99 %), while finer sub-micron dust passes out the vortex finder.

Why do multi-cyclone banks perform better than one giant cyclone?

Splitting flow across smaller-diameter cyclones increases centrifugal acceleration (v²/r) at the same inlet velocity, lowering d50.

What happens if cyclone inlet velocity is too high (> 26 m/s)?

Pressure drop climbs with v², abrasive wear accelerates rapidly on the volute and cone, and particle re-entrainment from the wall can reduce collection efficiency.

Your saved guides

Saved only in this browser. No account required.

Advertisement