Why a Centrifugal Pump Loses Prime and How to Stop It

The air paths that make a centrifugal pump lose prime, how much suction lift is realistic (with a worked example), and the fixes.

Jignesh S Panchal 6 min read
Why a Centrifugal Pump Loses Prime and How to Stop It (cover graphic)
Approx. 9 min read
On this page
  1. Centrifugal pump diagram: parts and their functions
  2. Where the air comes from
  3. How much suction lift is realistic?
  4. Worked example
  5. Fixing the problem
  6. Do not do this
  7. What I see in plants
  8. Worked example: how deep must the suction inlet be?
  9. Commissioning checklist for a lift or long suction line
  10. Frequently asked questions
  11. How do I prime a centrifugal pump?
  12. Why does my pump prime fine but lose it after an hour?
  13. Is a self-priming pump immune from air problems?
  14. Can I use a foot valve instead of a priming system?
  15. Sources and further reading
  16. More on Pumps, Valves and Piping

Short answer: a centrifugal pump loses prime when air gets into the casing or suction line and the impeller cannot move it. The usual sources are a leak on the suction side, a suction lift that is too high, a leaking foot valve, a vortex at the tank, or an air leak through the shaft seal. Find the air path first, then decide whether you need a self-priming pump or a priming system.

Centrifugal pump diagram: parts and their functions

Centrifugal pump diagram with labelled parts: suction nozzle, volute casing, impeller, discharge nozzle, shaft, mechanical seal, bearing housing, coupling, motor, baseplate and wear rings
Centrifugal pump diagram: an end-suction pump in cutaway side view, with its main parts numbered.
No. Part What it does
1 Suction nozzle Where the liquid enters, along the axis of the shaft.
2 Volute casing The spiral-shaped casing. Its widening passage slows the liquid and turns its speed into pressure.
3 Impeller The rotating wheel with curved vanes. It throws the liquid outward and gives it speed.
4 Discharge nozzle Where the pressurised liquid leaves the casing.
5 Shaft Transmits the torque from the motor to the impeller.
6 Mechanical seal Seals the point where the shaft leaves the casing, so the liquid does not leak along the shaft. Some pumps use gland packing instead.
7 Bearing housing Holds the bearings that support the shaft and take the loads from the impeller.
8 Coupling Connects the pump shaft to the motor shaft and allows for small misalignment.
9 Electric motor Drives the pump.
10 Baseplate A rigid frame that keeps the pump and the motor aligned.
11 Wear rings Replaceable rings that keep a small clearance between the impeller and the casing. They limit leakage from the discharge side back to the suction side and can be replaced as they wear.

Download this diagram (SVG)Schematic for learning. Real machines vary by maker and duty.

A standard centrifugal pump moves liquid, not air. If its casing fills with air, the impeller just churns it and builds almost no suction. In plants I visit, loss of prime is often described as “the pump just stops pumping at random.” It is not random. There is always an air path, and it usually appears after maintenance or when the tank level drops.

Where the air comes from

Source How to confirm
Loose suction flange or damaged gasket Bubbles or a hiss; brush soapy water on joints with the pump running, or pressurise the suction line with the pump stopped
Worn valve stem packing on the suction side Air enters through the gland when the line is in vacuum
Foot valve or non-return valve leaking Casing drains back when the pump stops; priming is lost each time
Vortex at the tank outlet Trouble appears only when the level falls; a swirl may be visible
Shaft seal or gland drawing air Air enters when suction pressure is below atmosphere. Packing or seal needs attention
Suction lift too high Calculation shows insufficient margin; see below
Liquid near boiling point Vapour forms in the suction and the pump vapour-locks
Air coming out of solution Liquids saturated with gas release bubbles when pressure falls

How much suction lift is realistic?

The water column that atmospheric pressure can support is about 10.3 m at sea level, but you can use only a fraction of that. You must also cover vapour pressure, friction, the pump’s NPSH required and a safety margin.

Advertisement

Worked example

Water at 30 °C, pump at sea level. NPSH required by the pump at the duty point is 3.0 m. Suction friction loss is 0.8 m.

  • Atmospheric head = 101,300 / (996 × 9.81) = 10.37 m
  • Vapour pressure head at 30 °C ≈ 4,200 / (996 × 9.81) = 0.43 m
  • Maximum lift = 10.37 − 0.43 − 3.0 − 0.8 − 0.6 (margin) = about 5.5 m

At a site 1,000 m above sea level, atmospheric pressure is roughly 89.9 kPa, or 9.2 m of water. The same arithmetic gives a maximum lift of only about 4.4 m. If your pump sits 6 m above the tank, it will struggle on any day. Move the pump down, push the liquid to it with a flooded suction, or choose a pump designed for lift.

Fixing the problem

  1. Seal the suction side. Re-make flanges with new gaskets, renew valve packing, and replace flexible hoses that have started to crack.
  2. Keep the suction line self-venting. Slope it continuously upward toward the pump. A horizontal run with an eccentric reducer installed flat-side up avoids air pockets.
  3. Raise submergence. Keep the pipe inlet well below the liquid surface. A bell-mouth inlet and a vortex breaker help.
  4. Fix or replace the foot valve. Or fit a non-return valve and a priming connection.
  5. Consider a priming system. A vacuum pump, ejector or priming tank can vent the casing automatically.
  6. Choose the right pump. Where lift or intermittent suction is unavoidable, a self-priming centrifugal pump is the correct tool. See how they work in our guide to self-priming centrifugal pumps.

Do not do this

  • Do not run the pump dry to “help it prime.” Mechanical seals and wear parts overheat in seconds. See mechanical seal failure analysis.
  • Do not tighten gland packing hard to stop air entry. You will burn the shaft sleeve.
  • Do not fit a larger pump to overcome a lift problem. A bigger pump needs more NPSH, not less.

What I see in plants

In many plants, the pump was installed as a flooded-suction pump and later moved or re-piped by the maintenance team to make space. A lift of two or three metres appeared where none was designed, and nobody revisited the calculation. In another common case, a tank level control was set lower to give more storage capacity, and the pump started losing prime only when the tank fell below a certain level.

When I talk to operators, they know exactly at which tank level the problem begins. That one number tells you whether it is a vortex or a lift problem.

Free tools for this topic: Pump power calculator · Pump affinity laws calculator · Equipment fault finder · all free engineering tools

Worked example: how deep must the suction inlet be?

Many “random” losses of prime are a vortex drawing air when the tank level falls. A widely used guideline from the Hydraulic Institute intake standard gives the minimum submergence above the inlet as S = D × (1 + 2.3 × Fr), where D is the inlet diameter and Fr = V / √(g × D) is the Froude number at the inlet. Illustrative case: a 150 mm inlet (D = 0.15 m) carrying 25 litres per second.

Advertisement
  • Inlet area = π × 0.15² / 4 = 0.01767 m²
  • Velocity V = 0.025 / 0.01767 = 1.41 m/s
  • √(9.81 × 0.15) = √1.472 = 1.213, so Fr = 1.41 / 1.213 = 1.16
  • S = 0.15 × (1 + 2.3 × 1.16) = 0.15 × 3.67 = 0.55 m

If the inlet sits 0.20 m above the tank floor, the liquid must not fall below about 0.20 + 0.55 = 0.75 m. Setting the low-level pump trip at around 0.85 m leaves a small margin. If operators say the trouble starts “when the tank is nearly empty” and the trip is set at 0.5 m, you have found the cause. Fitting a bell-mouth (which lowers inlet velocity) or a vortex breaker are the alternatives when the usable volume cannot be given up.

When prime is lost Most likely cause First check
Every time after a stop Foot valve or non-return valve leaking back Watch the casing drain or the suction gauge fall after stopping
Only at low tank level Vortex or insufficient submergence Compare the trip level with the submergence calculation
Gradually over an hour or more Small air leak on the suction side or gassy liquid Soap test on joints; check gland and seal
On hot days or with warm liquid Vapour pressure eating the NPSH margin Redo the lift calculation at the highest liquid temperature
Since maintenance or re-piping New high point, flange gasket or extra lift Walk the suction line and compare with the original layout

Commissioning checklist for a lift or long suction line

  • Suction line pressure-tested before start-up
  • Continuous rise toward the pump; eccentric reducer flat side up
  • Low-level trip set from a submergence calculation, not by habit
  • Lift calculation done at the site altitude and the hottest liquid temperature
  • Priming procedure written and posted at the pump

Frequently asked questions

How do I prime a centrifugal pump?

Fill the casing and suction pipe completely with liquid with the discharge valve slightly open to vent air, then start. Follow the manufacturer’s instructions for the specific pump and liquid.

Why does my pump prime fine but lose it after an hour?

That points to slow air ingress, a gas-laden liquid, or a tank level falling to a vortex point. Check seals and fittings on the suction side.

Is a self-priming pump immune from air problems?

No. It can re-prime after air enters, but it still needs liquid in the casing to start, and it has its own lift limits.

Can I use a foot valve instead of a priming system?

You can, but foot valves foul, leak and add friction loss. For critical duties, a proper priming system is more reliable.

Next on this topic: Pump Vibration: Telling Cavitation, Misalignment and Bearing Wear Apart and Pump Not Delivering Rated Flow: Nine Causes to Check in Order. This guide is part of our pumps pillar guide.

Further reading: Hydraulic Institute (pump standards and user guidance).

Advertisement

General guidance. Follow plant safety procedures and the pump manufacturer’s instructions.

Sources and further reading

For standards, data and independent guidance on this topic, see US Department of Energy pump systems resources (pump efficiency guidance), American Petroleum Institute (pump and seal standards) and The Engineering ToolBox (engineering reference data and calculators). Always check the current edition and your site conditions before applying any figure.

Free tool for this topic

Pump Power & Motor Size CalculatorHydraulic power, shaft power and recommended motor rating for centrifugal pumps from flow, head, density and efficiency.
Open calculator

Continue learning

More on Pumps, Valves and Piping

View all →
Sponsored
Jignesh S Panchal
Technical Editorial Author Verified Editor

Jignesh S Panchal

Founder — Jaadu Digital & Musafir Infotech · 9+ Years in Industrial B2B

Jignesh S Panchal is the founder of Jaadu Digital and Musafir Infotech, and the publisher behind EngiTech. With over 9 years of hands-on experience in industrial marketing and B2B growth, he works closely with machinery OEMs, process equipment manufacturers, and industrial service providers across thermal processing, fluid handling, automation, packaging, and plant reliability. Combining deep practical knowledge of industrial manufacturing with how technical buyers actually evaluate equipment, he built EngiTech to give plant engineers and procurement teams reliable sizing tools, fault diagnostics, and verified B2B supplier discovery.

Your saved guides

Saved only in this browser. No account required.

Advertisement