Total dynamic head (TDH) is the head a pump must add to move a specified flow through a defined system. It can include an elevation difference, a pressure difference, a change in velocity head and friction losses. Start by choosing the calculation boundaries: a tank-to-tank balance and a pump-nozzle balance use different measurement points.
Centrifugal pump diagram: parts and their functions
| No. | Part | What it does |
|---|---|---|
| 1 | Suction nozzle | Where the liquid enters, along the axis of the shaft. |
| 2 | Volute casing | The spiral-shaped casing. Its widening passage slows the liquid and turns its speed into pressure. |
| 3 | Impeller | The rotating wheel with curved vanes. It throws the liquid outward and gives it speed. |
| 4 | Discharge nozzle | Where the pressurised liquid leaves the casing. |
| 5 | Shaft | Transmits the torque from the motor to the impeller. |
| 6 | Mechanical seal | Seals the point where the shaft leaves the casing, so the liquid does not leak along the shaft. Some pumps use gland packing instead. |
| 7 | Bearing housing | Holds the bearings that support the shaft and take the loads from the impeller. |
| 8 | Coupling | Connects the pump shaft to the motor shaft and allows for small misalignment. |
| 9 | Electric motor | Drives the pump. |
| 10 | Baseplate | A rigid frame that keeps the pump and the motor aligned. |
| 11 | Wear rings | Replaceable rings that keep a small clearance between the impeller and the casing. They limit leakage from the discharge side back to the suction side and can be replaced as they wear. |
Download this diagram (SVG)Schematic for learning. Real machines vary by maker and duty.
My practical suggestion is to put the boundaries and units at the top of the calculation sheet. That makes it easier for a supplier or reviewer to see what is included, identify missing losses and avoid counting the same contribution twice.
1. Choose the calculation boundaries
For steady, incompressible flow of a single liquid through a system with one pump and no turbine, a useful energy balance between upstream point 1 and downstream point 2 is:
H = (p2 − p1)/(ρg) + (z2 − z1) + (v22 − v12)/(2g) + hL
- H: required pump head, metres of the pumped liquid.
- p: pressure at each boundary, Pa, using a consistent pressure reference.
- ρ: liquid density, kg/m³; g: gravitational acceleration, m/s².
- z: elevation relative to the same datum, m; v: mean velocity, m/s.
- hL: losses between the chosen boundaries, expressed as head, m.
At the free surfaces of two large tanks, the surface velocities may be negligible. If both tank surfaces are at the same pressure, the pressure-difference term cancels too. Neither simplification is valid automatically: a pressurized receiving vessel changes the duty even when its elevation stays the same.
For a pump-nozzle measurement, calculate the increase in total head between the suction and discharge measurement points from their pressure, velocity and elevation terms. Do not add the remote tank-to-tank static lift again to that measured increase. KSB’s head explanation distinguishes pump head from system head and explains their steady operating relationship.
2. Calculate losses with the right inputs
For a straight, full circular pipe, the Darcy–Weisbach relationship is hf = fD(L/D)v²/(2g). Here L is length and D is the actual inside diameter, both in metres. The factor fD is the Darcy friction factor, not the Fanning factor. For the same conditions, the Darcy factor is four times the Fanning factor.
Calculate mean velocity from v = 4Q/(πD²), with Q in m³/s. Determine the applicable friction factor using the flow regime, fluid viscosity and pipe roughness. Evaluate each pipe size separately. A nominal size is not a substitute for an inside diameter.
A local loss can be expressed as hlocal = Kv²/(2g) when K and its reference velocity are defined. Use fitting or valve data appropriate to the actual geometry and opening. Equipment such as filters and heat exchangers may have supplier pressure-drop curves instead. Account for credible fouled or dirty conditions as well as clean conditions, without adding a duplicated allowance.
KSB’s head-loss reference explains why roughness, internal diameter, valve design and flow conditions matter. A loss coefficient taken from a different arrangement is an assumption to investigate, not a verified equipment property.
3. Hypothetical worked example
Illustrative assumptions only: a water-like liquid with density 1,000 kg/m³ flows at 60 m³/h between large tanks. The receiving surface is 20 m higher and its pressure is 100,000 Pa higher. Surface velocities are negligible. Represent the route by 100 m of pipe with 0.100 m inside diameter, an assumed Darcy factor of 0.020 and an assumed combined K of 5 referenced to that pipe’s velocity. These factors are teaching inputs; they have not been derived for a real installation.
| Contribution | Calculation | Result |
|---|---|---|
| Flow conversion | 60 ÷ 3,600 | 0.016667 m³/s |
| Pipe velocity | 4Q/(πD²) | 2.122 m/s |
| Elevation head | z₂ − z₁ | 20.000 m |
| Pressure-difference head | 100,000/(1,000 × 9.80665) | 10.197 m |
| Straight-pipe loss | 0.020 × (100/0.100) × v²/(2g) | 4.592 m |
| Assumed local losses | 5 × v²/(2g) | 1.148 m |
| Required head at the stated flow | 20 + 10.197 + 4.592 + 1.148 | 35.937 m, approximately 35.94 m |
This result is conditional on every stated input. It does not establish NPSH adequacy, allowable pump operating range, equipment pressure rating, seal suitability or a motor rating. Those checks remain separate.
4. Build a system curve, not just one duty point
For the same hypothetical example, if the tank levels and pressures stay fixed and the friction factor and K remain constant, losses vary with flow squared. With Q now expressed in m³/h, the illustrative system curve is H(Q) = 30.197 + 5.740(Q/60)² metres, using rounded displayed coefficients.
| Flow | System head |
|---|---|
| 30 m³/h | 31.632 m |
| 60 m³/h | 35.937 m |
| 90 m³/h | 43.112 m |
Real friction factors can change with flow. Control valves, fluid properties, parallel branches, vessel pressures and liquid levels can also change the system curve. Model credible operating cases and compare them with the manufacturer’s pump curves. An intersection identifies a predicted operating point; it does not by itself establish an acceptable operating region.
5. Review the calculation before sending an RFQ
- Record minimum, normal and maximum flow, the fluid composition, temperature, density and viscosity.
- Identify the calculation boundaries, pressure reference and elevation datum.
- Check actual pipe IDs, lengths, roughness assumptions, branches, valves and equipment pressure drops.
- List uncertain inputs and show how their credible ranges affect head.
- Check NPSHa separately using the relevant suction conditions and pressure basis.
- Request the pump curve, efficiency and absorbed-power information, NPSH data and manufacturer operating limits for the proposed equipment.
- Review start-up, control, minimum-flow protection and transient conditions with the responsible engineer and supplier.
For a broader supplier brief, use the industrial process pump selection guide and Equipment Selection Desk.
Common questions about total dynamic head
Is TDH just the discharge pressure?
No. A pressure reading alone leaves out the suction-side reference, velocity and elevation differences. The terms required depend on whether you are describing a system balance or a measured pump head.
Should I add a fixed percentage as a head margin?
Do not treat a fixed percentage as universally correct. Document the uncertainties, model the relevant cases and agree the duty and selection basis with the responsible engineer and manufacturer. Increasing the flow allowance also changes friction losses.
Does a closed circulating loop require the building height as static lift?
For a fully filled closed loop returning to the same boundary, elevation gains and losses around the circuit cancel in the steady energy balance. Friction, equipment pressure drops and other imposed requirements remain. System pressurization and adequate suction pressure still require separate attention.
Can this example determine a motor size?
No. Motor selection needs the proposed pump’s absorbed power across the applicable operating cases, drive arrangement and manufacturer requirements. A single hydraulic-head example is insufficient.
Editorial update, 4 November 2026: Replaced the earlier inconsistent worked example, dependent diagrams and sizing claims with this explicitly hypothetical calculation. The arithmetic has been recalculated; no independent professional engineering certification or equipment test is claimed. See our editorial standards and corrections policy.
Free tools for this topic: Pump power calculator · Pump affinity laws calculator · Equipment fault finder · all free engineering tools
Sources and further reading
For standards, data and independent guidance on this topic, see Hydraulic Institute (pump standards and user guidance), US Department of Energy pump systems resources (pump efficiency guidance) and American Petroleum Institute (pump and seal standards). Always check the current edition and your site conditions before applying any figure.
Free tool for this topic
Pump Power & Motor Size CalculatorHydraulic power, shaft power and recommended motor rating for centrifugal pumps from flow, head, density and efficiency.
Pumps, Valves and PipingCryogenic Liquid Pump Sizing: LNG, Liquid Oxygen & Thermal Insulation
Pumps, Valves and PipingOrifice Plate Flow Meter Sizing: ISO 5167 Calculation & Beta Ratio
Pumps, Valves and PipingPump Minimum Continuous Stable Flow (MCSF): Thermal Rise & Recirculation Math
Pumps, Valves and PipingPump Affinity Laws Calculation Formula: Speed & Impeller Trimming Math
Pumps, Valves and PipingNPSHa Calculation Formula for Centrifugal Pumps: Margin Ratios & Standards
Pumps, Valves and PipingIndustrial Process Pumps Selection Guide: Sizing, System Head Curves & Standards