New in the library Presented by Jaadu Digital ↗
Free Business Profile Free tools

Metric & Imperial Bolt Torque Chart (ISO 898-1 Class 8.8, 10.9, 12.9 & SAE Grade 5/8)

Interactive Metric ISO 898-1 (8.8, 10.9, 12.9, A2-70) & SAE Grade 5/8 / B7 bolt torque calculator and chart with K-factor lubrication, preload, and N·m / ft-lb.

Tightening Torque——
Clamp Preload Force——
Tensile Stress Area——
Nut Factor (K)0.20—
Preload within safe elastic proof envelope.
Size & PitchStress AreaSelected Grade Torque (N·m)Torque (ft-lb)Clamp Load (kN / lbf)Hex AF
Embed this free tool on your website or blog

Free to embed on engineering blogs, university guides, and plant wikis (zero login required).

1 2 3 4 5 6 7 8 ASME PCC-1 3-Pass Star Bolting Sequence Pass 1 (30% Torque): Snug gasket uniformly in 1 -> 2 -> 3 -> 4 -> 5 -> 6 -> 7 -> 8 order. Pass 2 (60% Torque): Repeat star sequence; check flange gap at 4 quadrants with feeler gauge. Pass 3 (100% Torque): Full target torque in star order, then 1 final clockwise check pass at 100%. Tip: Re-torque carbon steel steam flanges once after 24 h hot service if gasket relaxes.

8-Bolt flange star sequence — prevents gasket pinching and flange cocking during plant hydrotest.

Shop-Floor Formula & Why K-Factor Matters

T = K × d × Fi  |  Fi = %Proof × Sp × As

Where T is tightening torque (N·m), K is the dimensionless nut factor, d is nominal diameter (m), and Fi is clamp preload (N). About 50% of wrench effort burns up under the nut face and another 40% in thread flank friction — only ~10% actually stretches the bolt.

That is why slapping nickel anti-seize (K = 0.13) onto an ASME B16.5 Class 300 flange stud and still pulling the dry torque spec (K = 0.20) spikes bolt tension by 54%. Either neck the stud or check your lube K-factor first.

Workshop Commissioning Pitfalls

  • Never trust uncalibrated air impacts: Snug with an impact, finish with a calibrated click or hydraulic torque wrench.
  • Hardened washers under turned nuts: Always place an ASTM F436 / DIN 6916 washer under the rotating nut so it does not gouge painted flange faces and falsify K.
  • Check material hardness first: Verify stud and nut grade stamps before assembly using our HRC / HBW Hardness Conversion Chart, and pair with ASME B36.10 Pipe Schedule dimensions.

Frequently Asked Questions

Why does anti-seize or MoS2 grease change the tightening torque so drastically?

Dry steel-on-steel threads waste roughly 85-90% of your wrench torque overcoming friction (K ~ 0.20). Nickel anti-seize or MoS2 drops K to ~0.12-0.13. If you pull a greased stud to a dry torque number, preload jumps 50%+ and stretches or snaps the bolt before hydrotest.

How do I convert N·m to ft-lb on the workshop floor?

Divide N·m by 1.35582 to get ft-lb (or multiply ft-lb by 1.35582 to get N·m). For smaller M4-M8 fasteners under 15 N·m, multiply N·m by 8.8507 to read in-lb.

Why tighten flange and gearbox covers in a 30% -> 60% -> 100% star pattern?

Pulling one bolt straight to 100% pinches the gasket on one side and cocks the flange face. Three progressive star passes (30%, 60%, 100%) plus one final circular check pass seat spiral-wound and CAF gaskets evenly.

What target preload percentage is safe for stainless A2-70 / A4-70 bolts?

Keep austenitic stainless bolts around 60-65% of 0.2% proof strength (Rp0.2) and always use PTFE or nickel anti-seize at low wrenching speed. High-speed impact guns overheat stainless threads and cause instant cold-weld galling.

Jignesh S Panchal
Technical Editorial Author Verified Editor

Jignesh S Panchal

Founder — Jaadu Digital & Musafir Infotech · 9+ Years in Industrial B2B

Jignesh S Panchal is the founder of Jaadu Digital and Musafir Infotech, and the publisher behind EngiTech. With over 9 years of hands-on experience in industrial marketing and B2B growth, he works closely with machinery OEMs, process equipment manufacturers, and industrial service providers across thermal processing, fluid handling, automation, packaging, and plant reliability. Combining deep practical knowledge of industrial manufacturing with how technical buyers actually evaluate equipment, he built EngiTech to give plant engineers and procurement teams reliable sizing tools, fault diagnostics, and verified B2B supplier discovery.

Your saved guides

Saved only in this browser. No account required.

Advertisement