On this page
- 1. Multiphase Flow Fundamentals: Superficial Velocities & Holdup
- 2. The Lockhart-Martinelli Parameter (X)
- 3. The Chisholm Two-Phase Multipliers (PhiL² and PhiG²)
- 4. Total Two-Phase Pressure Gradient: Friction, Elevation & Acceleration
- 5. Industrial Worked Example: Multiphase Hydrocarbon Gathering Line
- Step-by-Step Mathematical Calculations
- Frequently Asked Questions on Two-Phase Gas-Liquid Flow
- Sources and further reading
- More on Machinery and Equipment
In petroleum extraction pipelines, oil and gas gathering lines, chemical distillation thermosiphon reboilers, geothermal steam headers, and refrigeration evaporators, fluids rarely travel as homogeneous single-phase substances. Instead, gas vapor and liquid coexist, interacting dynamically as they travel through the pipe.
Because gas possesses lower viscosity and density than liquid, it accelerates to significantly higher linear velocities, creating interfacial shear drag across the liquid boundary. Depending on relative superficial phase velocities and fluid physical properties, the two-phase mixture organises into distinct flow regimes: stratified smooth, stratified wavy, intermittent slug, plug, annular mist, or dispersed bubbly flow. Attempting to model these multiphase systems using single-phase formulas from our Darcy-Weisbach calculation guide drastically underestimates friction losses, leading to starved distillation towers, choked pipelines, and destructive pipe vibration. Accurately sizing multiphase lines requires combining the hydraulic routing rules in our industrial piping systems design guide, minor resistance factors from our pipe fitting K-factor guide, and valve choking mechanics from our control valve sizing guide.
1. Multiphase Flow Fundamentals: Superficial Velocities & Holdup
When liquid and gas flow concurrently through a pipe of internal cross-sectional area A, each phase occupies only a portion of the pipe cross section. The volume fraction of the pipe occupied by gas is defined as the Void Fraction (α), while the fraction occupied by liquid is the Liquid Holdup (RL or HL):
vSL = QLA = dot{m}LρL · A qquad vSG = QGA = dot{m}GρG · A
Actual In-Situ Velocities: vL = QLAL = vSLRL qquad vG = QGAG = vSGalpha
Phase Slip Ratio: S = vGvL = vSG · RLvSL · alpha ≥ 1.0
Where:
- vSL = Superficial liquid velocity (velocity if liquid occupied the entire pipe cross section alone, m/s)
- vSG = Superficial gas velocity (velocity if gas occupied the entire pipe cross section alone, m/s)
- S = Slip ratio; because gas has much lower density and viscosity, vG > vL, making $S > 1.0$ in almost all practical industrial conditions
2. The Lockhart-Martinelli Parameter (X)
In their seminal 1949 work, R.W. Lockhart and R.C. Martinelli formulated the separated flow model. Rather than treating the mixture as a pseudo-homogeneous fluid, they proposed that the two-phase frictional pressure drop can be related directly to single-phase pressure drops through a dimensionless parameter X:
Where:
- (dP/dL)f,L = Frictional pressure gradient if the liquid phase were flowing alone in the pipe at mass flow rate dot{m}L (Pa/m)
- (dP/dL)f,G = Frictional pressure gradient if the gas phase were flowing alone in the pipe at mass flow rate dot{m}G (Pa/m)
The calculation of single-phase pressure gradients depends on the flow regime of each phase evaluated using superficial Reynolds numbers:
| Regime Designation | Liquid Phase (ReL) | Gas Phase (ReG) | Chisholm Coefficient (C) | Typical Industrial Fluid Process |
|---|---|---|---|---|
| Turbulent-Turbulent (tt) | ReL > 2,000 (Turbulent) | ReG > 2,000 (Turbulent) | C = 20 | Oil & gas gathering lines; steam reboilers; relief discharge headers |
| Viscous-Turbulent (vt) | ReL ≤ 2,000 (Laminar) | ReG > 2,000 (Turbulent) | C = 12 | Heavy viscous crude oil flow with gas lift injection |
| Turbulent-Viscous (tv) | ReL > 2,000 (Turbulent) | ReG ≤ 2,000 (Laminar) | C = 10 | Rare; high liquid mass flow with low gas density in capillary tubes |
| Viscous-Viscous (vv) | ReL ≤ 2,000 (Laminar) | ReG ≤ 2,000 (Laminar) | C = 5 | Micro-channel heat sinks; low-speed laboratory test loops |
3. The Chisholm Two-Phase Multipliers (PhiL² and PhiG²)
Lockhart and Martinelli originally presented their correlation as empirical graphical charts. In 1967, D. Chisholm derived an explicit algebraic formulation that models the graphical curves:
PhiG² = 1 + C · X + X²
Two-Phase Frictional Drop: (dPdL)2phi = PhiL² · (dPdL)L = PhiG² · (dPdL)G
Where:
- PhiL² = Two-phase liquid friction multiplier, dimensionless
- PhiG² = Two-phase gas friction multiplier, dimensionless
- C = Chisholm parameter dictated by regime matrix (20, 12, 10, or 5)
4. Total Two-Phase Pressure Gradient: Friction, Elevation & Acceleration
In real plant piping, the total pressure gradient (dP/dL)total comprises three physical components:
(dPdL)friction = PhiL² · (dPdL)f,L
(dPdL)elevation = ρm · g · sin(θ) qquad (ρm = RL · ρL + α · ρG)
(dPdL)acceleration = dot{m}total² · ddL left[x²α · ρG + (1 – x)²RL · ρL]
Where:
- $ heta$ = Angle of pipe inclination relative to horizontal (sin(θ) = 0 for horizontal lines; sin(θ) = 1.0 for vertical upward flow)
- hom = Mean two-phase in-situ density based on liquid holdup (RL)
- Acceleration Term: Becomes significant when pressure drops rapidly near choked conditions, causing flashing or gas expansion
5. Industrial Worked Example: Multiphase Hydrocarbon Gathering Line
To illustrate the calculation, consider a multiphase oil and associated gas gathering line transporting fluid from an offshore wellhead platform to a central separation facility.
| Process Design Parameter | Notation | Engineering Value | Data Source & Standard Basis |
|---|---|---|---|
| Nominal Pipe Size | NPS | 6-inch Schedule 40 (DN 150) | ASME B36.10M standard dimensions |
| Internal Pipe Diameter | di | 154.06 mm = 0.15406 m | Do = 168.28 mm, t = 7.11 mm |
| Cross-Sectional Flow Area | A | 0.01864 m² (0.2006 ft²) | A = π · di² / 4 |
| Total Mass Flow Rate | dot{m}total | 25.0 kg/s = 90,000.0 kg/h | Wellhead multiphase production rate |
| Gas Mass Quality Fraction | x | 0.150 ($15.0%$ gas, $85.0%$ liquid) | Reservoir gas-oil ratio (GOR) flash analysis |
| Liquid Hydrocarbon Density | hoL | 820.0 kg/m³ (51.19 lb/ft³) | Crude oil density at flowing conditions |
| Liquid Dynamic Viscosity | μL | 2.50 × 10-3 Pacdots (2.50 cP) | Crude oil viscosity at operating temperature |
| Associated Gas Density | hoG | 18.50 kg/m³ (1.155 lb/ft³) | Natural gas density at 25 bar(g) operating pressure |
| Gas Dynamic Viscosity | μG | 1.40 × 10-5 Pacdots (0.014 cP) | Hydrocarbon vapor viscosity |
| Pipeline Total Length | L | 500.0 m (1,640 ft) | Horizontal gathering pipeline distance |
| Pipe Surface Roughness | epsilon | 0.045 mm (0.00015 ft) | Standard commercial carbon steel pipe |
Step-by-Step Mathematical Calculations
Step 1: Calculate Superficial Velocities & Phase Reynolds Numbers
Gas Mass Flow: dot{m}G = x · dot{m}total = 0.15 · 25.0 = 3.75 kg/s
vSL = dot{m}LρL · A = 21.25 kg/s820.0 kg/m³ · 0.01864 m² = 21.2515.2848 = 1.3903 m/s
vSG = dot{m}GρG · A = 3.75 kg/s18.50 kg/m³ · 0.01864 m² = 3.750.34484 = 10.8746 m/s
ReL = ρL · vSL · diμL = 820.0 · 1.3903 · 0.154062.50 × 10-3 = 175.6360.0025 = 70,254 quad (Turbulent: ReL > 2,000)
ReG = ρG · vSG · diμG = 18.50 · 10.8746 · 0.154061.40 × 10-5 = 30.9930.000014 = 2,213,800 quad (Turbulent: ReG > 2,000)
Regime Identification: Both liquid and gas phases are fully turbulent. The regime is Turbulent-Turbulent (tt), establishing the Chisholm parameter C = 20.0.
Step 2: Calculate Single-Phase Friction Factors & Pressure Gradients
Liquid Darcy Friction Factor (Colebrook-White at ReL = 70,254): fL ≈ 0.0210
(dPdL)f,L = fL · ρL · vSL²2 · di = 0.0210 · 820.0 · (1.3903)²2 · 0.15406 = 0.0210 · 1,585.040.30812 = 108.03 Pa/m
Gas Darcy Friction Factor (Colebrook-White at ReG = 2,213,800): fG ≈ 0.0152
(dPdL)f,G = fG · ρG · vSG²2 · di = 0.0152 · 18.50 · (10.8746)²2 · 0.15406 = 0.0152 · 2,187.740.30812 = 107.92 Pa/m
Step 3: Calculate Lockhart-Martinelli Parameter (Xtt) & Chisholm Multiplier (PhiL²)
PhiL² = 1 + CX + 1X² = 1 + 20.01.0005 + 1(1.0005)² = 1 + 19.990 + 0.999 = 21.989 ≈ 22.00
Physical Significance: The two-phase friction multiplier PhiL² = 22.0 indicates that the concurrent two-phase mixture creates 22 times more frictional resistance than if the liquid phase were flowing alone in the pipeline!
Step 4: Calculate Total Two-Phase Frictional Pressure Drop (Δ P2phi)
Total Pipeline Frictional Drop (over 500 m): Δ P2phi = 2,375.5 Pa/m · 500.0 m = 1,187,750 Pa = 1.188 bar quad (17.23 psi)
Comparison with Incorrect Single-Phase Assumption: If an engineer had sized this line assuming simple liquid flow, the calculated drop would have been only 108.03 · 500 = 54.0 kPa = 0.54 bar. Underestimating the pressure drop by over $100%$ would lead to severe wellhead choking and pump cavitational back-pressure.
Free tools for this topic: Engineering unit converter · Engineering reference tables · Engineering glossary · all free engineering tools
Frequently Asked Questions on Two-Phase Gas-Liquid Flow
Sources and further reading
For standards, data and independent guidance on this topic, see Bureau of Indian Standards (Indian standards catalogue), NIST (measurement and calibration standards), The Engineering ToolBox (engineering reference data and calculators) and UK Health and Safety Executive (free safety guidance and case studies). Always check the current edition and your site conditions before applying any figure.
Free tool for this topic
Pipe Pressure Drop Calculator (Darcy–Weisbach)Velocity, Reynolds number, friction factor and pressure drop for liquids and gases in pipes, including fittings.
Machinery and EquipmentConveyor Belt Splicing: Hot Vulcanised, Cold and Mechanical Joints Compared
Machinery and EquipmentFilter Cake Washing: Displacement, Reslurry and How Many Wash Volumes
Machinery and EquipmentThe Ultimate Guide to Magnetic Conveyors: Everything You Need to Know
Machinery and EquipmentComprehensive Guide to Jackhammers
Machinery and EquipmentThe Future of Welding: Innovations in Welding Machines
Machinery and EquipmentZigzag Sewing Machines: A Comprehensive Guide for Knowledge Seekers, Students, and Working Professionals