New in the library Presented by Jaadu Digital ↗
Free Business Profile Free tools
Pumps, Valves and Piping

Pump Start-Up and Shutdown Checklist for Operators

A practical start-up and shutdown checklist for centrifugal pumps with reasons for each step, a starting current note and a water hammer worked example.

Jignesh S Panchal 7 min read
Pump Start-Up and Shutdown Checklist for Operators (cover graphic)
Approx. 9 min read
On this page
  1. Centrifugal pump diagram: parts and their functions
  2. Before the first start of the day
  3. Starting
  4. Why the starting current matters
  5. Stopping and the water hammer risk
  6. Worked example
  7. Shutdown steps
  8. What I see in plants
  9. Worked example: how fast a pump heats up against a closed valve
  10. Closed-valve running rules for the card
  11. Frequently asked questions
  12. Should the discharge valve be closed when starting a pump?
  13. How many times can I start a motor per hour?
  14. Why does my check valve slam?
  15. What readings should I log?
  16. Sources and further reading
  17. More on Pumps, Valves and Piping

Short answer: before starting a pump, confirm it is safe to run, the casing is full of liquid, the suction is open, the discharge is ready, and the driver and coupling are clear. Start with the discharge valve slightly open, watch pressure and current rise, then open slowly to duty. For shutdown, close the discharge slowly before stopping, so you avoid water hammer and reverse flow.

Centrifugal pump diagram: parts and their functions

Centrifugal pump diagram with labelled parts: suction nozzle, volute casing, impeller, discharge nozzle, shaft, mechanical seal, bearing housing, coupling, motor, baseplate and wear rings
Centrifugal pump diagram: an end-suction pump in cutaway side view, with its main parts numbered.
No. Part What it does
1 Suction nozzle Where the liquid enters, along the axis of the shaft.
2 Volute casing The spiral-shaped casing. Its widening passage slows the liquid and turns its speed into pressure.
3 Impeller The rotating wheel with curved vanes. It throws the liquid outward and gives it speed.
4 Discharge nozzle Where the pressurised liquid leaves the casing.
5 Shaft Transmits the torque from the motor to the impeller.
6 Mechanical seal Seals the point where the shaft leaves the casing, so the liquid does not leak along the shaft. Some pumps use gland packing instead.
7 Bearing housing Holds the bearings that support the shaft and take the loads from the impeller.
8 Coupling Connects the pump shaft to the motor shaft and allows for small misalignment.
9 Electric motor Drives the pump.
10 Baseplate A rigid frame that keeps the pump and the motor aligned.
11 Wear rings Replaceable rings that keep a small clearance between the impeller and the casing. They limit leakage from the discharge side back to the suction side and can be replaced as they wear.

Download this diagram (SVG)Schematic for learning. Real machines vary by maker and duty.

Operators ask me for a one-page checklist more often than for any technical paper. In many plants the start-up routine lives in someone’s head, and shifts do it differently. Differences between shifts show up later as seal failures or unexplained trips. Here is a checklist I would put on the wall beside a pump, with the reasoning behind each step.

Before the first start of the day

Check Why
Lock-out and permit closed, guards fitted Safety; coupling guard prevents injury
Rotate the shaft by hand (small pumps) Detects seizure, rubbing, or a foreign object
Oil level and grease in bearing housings; cooling water on Prevents bearing damage at start
Seal flush or quench valves open, gland packing adjusted A seal running dry fails within seconds
Suction valve fully open; strainer clean Avoids cavitation and starved start
Casing primed, vented to remove air A dry or air-bound pump will not pump and may damage the seal
Discharge valve closed or slightly open (as per the pump type) Reduces starting load on most radial pumps
Minimum flow line or bypass available Protects against low-flow heating; see minimum flow
Gauges are working and valves on the gauge lines are open You need the readings to judge the start
Rotation direction confirmed after any electrical work A bump start is enough

Starting

  1. Press start and listen immediately. Look at the suction and discharge gauges and motor current.
  2. Within seconds the discharge pressure should rise to the shutoff value on the pump curve. If it doesn’t, stop. The pump is air-bound or reversed.
  3. Open the discharge valve slowly while watching current and pressure. Don’t allow flow to exceed the rated value.
  4. Check for leaks at the seal, flanges and glands.
  5. Check noise and vibration. Gravel noise suggests cavitation; a rumble suggests bearings.
  6. After 15 to 30 minutes, check bearing temperatures and seal condition, and write down the readings.

Why the starting current matters

An induction motor takes about six to seven times its full-load current during starting. For an 18.5 kW motor at 415 V, the full-load current is roughly 32 A, so starting may reach about 200 A for a few seconds. Do not repeat starts quickly. Motor makers limit the number of starts per hour, and repeated starts heat the windings. If the plant makes frequent starts, ask for the motor’s allowed number.

Advertisement

Stopping and the water hammer risk

If a long discharge pipe is full and the pump stops suddenly, the liquid column slows, may reverse and then slam against the non-return valve. A sudden closing of any valve in a line with moving liquid does the same. The pressure rise can be estimated with the Joukowsky equation: Δp = ρ × a × Δv, where a is the pressure wave speed.

Worked example

Water flowing at 1.5 m/s in a steel pipe is stopped suddenly. Wave speed in a steel pipe is typically near 1,000 m/s.

  • Δp = 1,000 kg/m³ × 1,000 m/s × 1.5 m/s = 1.5 × 10⁶ Pa = about 15 bar above the normal pressure.

That is enough to burst a flange, shift a support or break a gauge. The effect applies only if the closure is faster than 2L/a (the time for the wave to travel to the end of the line and back). For a 500 m pipe, 2L/a is about one second, so closing a valve over 30 seconds avoids the worst of it. Practical measures: close the discharge valve slowly before stopping, use soft-closing non-return valves, add surge vessels or a flywheel on long lines, and ask a specialist to run a surge study for long or high-pressure pipelines.

Shutdown steps

  1. Slowly close the discharge valve to the minimum flow or near closed.
  2. Stop the pump.
  3. Close the suction and discharge valves if the pump will be isolated.
  4. Shut off seal water and cooling water when the pump is cold, unless the seal plan says otherwise.
  5. If the pump is going out for maintenance, drain, flush and isolate per the permit.
  6. Note any observations in the log.

What I see in plants

When I walk through plants with operators, most of them already follow this routine in a loose way. What is missing is a paper record. A simple card at the pump with a column for “suction pressure, discharge pressure, current, bearing temperature” filled each shift builds the baseline needed for any troubleshooting. It costs nothing and gets used. It also helps new staff learn what normal looks like.

Another point: a startup procedure is shortest when the system is set up to be started easily. Valves that are hard to reach or gauges that are broken make people skip steps. Fixing the layout is part of the procedure.

Free tools for this topic: Pump power calculator · Pump affinity laws calculator · Equipment fault finder · all free engineering tools

Advertisement

Worked example: how fast a pump heats up against a closed valve

The checklist allows starting with the discharge valve closed or nearly closed, but only briefly. With no flow, almost all the power going into the pump turns into heat in the small amount of liquid in the casing. Assume (illustratively) a pump absorbing 9 kW at shutoff with 15 litres of water in its casing, and ignore heat lost to the surroundings, which is small over a few minutes.

  • Heating rate = power ÷ (mass × specific heat) = 9,000 ÷ (15 × 4,186) = 0.14 K per second, or about 8.6 K per minute.
  • Starting at 30 °C, the water reaches 80 °C after (80 − 30) ÷ 8.6 = about 5.8 minutes. Long before that, the seal faces lose their liquid film and the wear rings can rub.
  • To hold the temperature rise to 5 K in continuous running, the pump needs a flow of at least 9,000 ÷ (1,000 × 4,186 × 5) = 0.00043 m³/s, or about 1.5 m³/h.
Condition Result for this example
Heating rate with no flow about 8.6 K per minute
Time from 30 °C to 80 °C about 6 minutes
Flow to limit the rise to 5 K about 1.5 m³/h

That 1.5 m³/h is only the thermal minimum. Most pump makers state a higher minimum continuous stable flow, set by vibration and internal recirculation rather than heat, and that figure governs. Read it from the pump data sheet and write it on the checklist card, so the operator knows how far the discharge valve must be open before leaving the pump.

Closed-valve running rules for the card

  • Open the discharge valve within one minute of the pressure reaching shutoff
  • Never leave a pump running with the discharge closed and unattended
  • If the casing feels hot or the seal hisses, stop the pump and investigate
  • Check that the minimum flow line valve is open before starting pumps that have one

Frequently asked questions

Should the discharge valve be closed when starting a pump?

For most radial centrifugal pumps, start with it closed or slightly open to reduce power. Mixed-flow and axial pumps behave differently, so follow the manufacturer.

How many times can I start a motor per hour?

It depends on the motor. Check the maker’s data; many allow only a few starts an hour for large motors.

Why does my check valve slam?

Flow reverses before it closes. Use a spring-assisted or nozzle-type check valve, or slow the shutdown.

What readings should I log?

Suction pressure, discharge pressure, motor current, flow if available, and bearing and seal temperatures.

You may also want: Pump Efficiency Test: Measuring Duty Point With Gauges and a Clamp-On Meter and Sizing a Pump Motor: Margin, Service Factor and Starting Method. This guide is part of our pumps pillar guide.

Advertisement

Further reading: Hydraulic Institute (pump standards and user guidance).

General guidance. Follow the pump manufacturer’s start-up procedure and plant safety rules.

Sources and further reading

For standards, data and independent guidance on this topic, see US Department of Energy pump systems resources (pump efficiency guidance), American Petroleum Institute (pump and seal standards) and The Engineering ToolBox (engineering reference data and calculators). Always check the current edition and your site conditions before applying any figure.

Free tool for this topic

Pump Power & Motor Size CalculatorHydraulic power, shaft power and recommended motor rating for centrifugal pumps from flow, head, density and efficiency.
Open calculator

Continue learning

More on Pumps, Valves and Piping

View all →
Sponsored
Jignesh S Panchal
Technical Editorial Author Verified Editor

Jignesh S Panchal

Founder — Jaadu Digital & Musafir Infotech · 9+ Years in Industrial B2B

Jignesh S Panchal is the founder of Jaadu Digital and Musafir Infotech, and the publisher behind EngiTech. With over 9 years of hands-on experience in industrial marketing and B2B growth, he works closely with machinery OEMs, process equipment manufacturers, and industrial service providers across thermal processing, fluid handling, automation, packaging, and plant reliability. Combining deep practical knowledge of industrial manufacturing with how technical buyers actually evaluate equipment, he built EngiTech to give plant engineers and procurement teams reliable sizing tools, fault diagnostics, and verified B2B supplier discovery.

Your saved guides

Saved only in this browser. No account required.

Advertisement