How to Read a Pump Performance Curve With a Worked Duty Point

Read a centrifugal pump curve step by step: head, efficiency, power and NPSH, with a worked system curve and duty point.

Jignesh S Panchal 6 min read
How to Read a Pump Performance Curve With a Worked Duty Point (cover graphic)
Approx. 9 min read
On this page
  1. Centrifugal pump diagram: parts and their functions
  2. What the lines on a curve mean
  3. The system curve
  4. Worked example: finding the duty point
  5. Power at the duty point
  6. Throttling or slowing: what it costs
  7. Four mistakes in reading curves
  8. What I see in plants
  9. Worked example: throttling versus slowing the same pump
  10. Checklist when a pump’s flow changes
  11. Frequently asked questions
  12. What is the best efficiency point?
  13. Why does a pump curve fall as flow rises?
  14. Can I use the same curve for different liquids?
  15. What does trimming an impeller do?
  16. Sources and further reading
  17. More on Pumps, Valves and Piping

Short answer: a pump curve shows the head a pump can produce at each flow. The pump runs where that curve crosses the system curve, which is the head the pipework and process need at each flow. Read the curve for four things at the duty point: head, efficiency, power and NPSH required, and make sure the point is inside the pump’s preferred operating range.

Centrifugal pump diagram: parts and their functions

Centrifugal pump diagram with labelled parts: suction nozzle, volute casing, impeller, discharge nozzle, shaft, mechanical seal, bearing housing, coupling, motor, baseplate and wear rings
Centrifugal pump diagram: an end-suction pump in cutaway side view, with its main parts numbered.
No. Part What it does
1 Suction nozzle Where the liquid enters, along the axis of the shaft.
2 Volute casing The spiral-shaped casing. Its widening passage slows the liquid and turns its speed into pressure.
3 Impeller The rotating wheel with curved vanes. It throws the liquid outward and gives it speed.
4 Discharge nozzle Where the pressurised liquid leaves the casing.
5 Shaft Transmits the torque from the motor to the impeller.
6 Mechanical seal Seals the point where the shaft leaves the casing, so the liquid does not leak along the shaft. Some pumps use gland packing instead.
7 Bearing housing Holds the bearings that support the shaft and take the loads from the impeller.
8 Coupling Connects the pump shaft to the motor shaft and allows for small misalignment.
9 Electric motor Drives the pump.
10 Baseplate A rigid frame that keeps the pump and the motor aligned.
11 Wear rings Replaceable rings that keep a small clearance between the impeller and the casing. They limit leakage from the discharge side back to the suction side and can be replaced as they wear.

Download this diagram (SVG)Schematic for learning. Real machines vary by maker and duty.

In meetings with plant engineers, the pump curve is the document everyone has seen and few have used. It is usually in a file somewhere. Yet it answers most of the questions people ask about a pump: why flow changed, why the motor is hot, why the pump is noisy. This article walks through reading one with a numerical duty point, using only simple arithmetic.

What the lines on a curve mean

Line What it shows
Head versus flow (H-Q) Falling curve: head is highest at zero flow and falls as flow rises
Efficiency versus flow A hill-shaped line. The top is the best efficiency point (BEP)
Power versus flow Shaft power needed. Often rises with flow for radial pumps
NPSH required versus flow Rises with flow. Compare with your NPSH available
Impeller diameter lines Show the effect of trimming the impeller

Pumps operate best near BEP. A widely used guide, from the Hydraulic Institute, is to keep operation within roughly 70 to 120 per cent of BEP flow. Outside that range, bearing and seal life, vibration and noise get worse.

Advertisement

The system curve

The system curve is the head the pipework needs at each flow: static head plus friction, which rises with the square of flow.

Hsystem = Hstatic + k × Q²

Worked example: finding the duty point

A system has 20 m of static head and 15 m of friction at 100 m³/h.

  • k = 15 / 100² = 0.0015
  • At 80 m³/h: 20 + 0.0015 × 6,400 = 29.6 m
  • At 100 m³/h: 20 + 15 = 35 m
  • At 120 m³/h: 20 + 0.0015 × 14,400 = 41.6 m

The pump curve reads: 55 m at zero flow, 52 m at 60 m³/h, 45 m at 100 m³/h, 39 m at 120 m³/h, 30 m at 140 m³/h.

At 100 m³/h the pump can give 45 m but the system needs only 35 m. At 120 m³/h the pump gives 39 m but the system needs 41.6 m. The curves cross between those two, at about 116 m³/h and 40 m.

That is your real duty point. The pump delivers 116 m³/h, not 100. If you need exactly 100 m³/h, there are three ways to get there: throttle a valve, trim the impeller, or slow the pump with a variable speed drive.

Advertisement

Power at the duty point

Say efficiency at 116 m³/h is 72 per cent.

  • Flow = 116 / 3,600 = 0.0322 m³/s
  • Hydraulic power = 0.0322 × 40.2 × 1,000 × 9.81 = 12.7 kW
  • Shaft power = 12.7 / 0.72 = 17.6 kW

Check that the motor has margin for this, with the pump power calculator. Our motor selection guide explains how to choose that margin.

Throttling or slowing: what it costs

To get 100 m³/h by throttling, the valve must absorb the difference between what the pump produces (45 m) and what the system needs (35 m), which is 10 m of head. That 10 m is wasted energy turned into heat and noise. Slowing the pump instead moves the pump curve down, so the valve is not needed. Use the pump affinity laws calculator to find the speed, and check the saving with the VFD energy savings calculator.

Four mistakes in reading curves

  1. Using the wrong speed or impeller. A curve for 1,450 rpm doesn’t apply at 2,900 rpm, or to a trimmed impeller.
  2. Reading head as pressure. Head is in metres of the liquid being pumped. Convert for density. A liquid with a specific gravity of 1.2 gives 20 per cent more pressure for the same head.
  3. Forgetting viscosity. Pump curves are for water. A viscous liquid reduces flow, head and efficiency, and needs correction factors.
  4. Ignoring NPSH required. A good duty point can still cavitate.

What I see in plants

A lot of the pumps I see were bought on a duty point that was later changed, because of valves added, filters changed, or production increased. The curve in the file is for the old duty. I suggest to plant teams that they mark the real duty point in ink on a copy of the curve and keep it next to the pump. It is the cheapest tool I know for catching drift.

Another thing I hear: “the supplier said it is the best pump for our application.” The curve lets you check that claim in five minutes. If your duty point is far to the right of BEP, the pump is working hard for the wrong reasons.

Free tools for this topic: Pump power calculator · Pump affinity laws calculator · Equipment fault finder · all free engineering tools

Worked example: throttling versus slowing the same pump

Take the duty above and suppose the process needs exactly 100 m³/h (0.02778 m³/s). The efficiencies used here are assumed; read yours from the curve.

Advertisement
  • Throttled: the pump runs at 100 m³/h on its full-speed curve, producing 45 m. Hydraulic power = 0.02778 × 45 × 1,000 × 9.81 = 12,263 W. At an assumed 70 per cent efficiency, shaft power = 12.26 / 0.70 = 17.5 kW.
  • Slowed: the pump only has to produce the 35 m the system needs at 100 m³/h. By the affinity laws, a point on the full-speed curve at flow Q/n and head H moves to Q and n² × H at speed ratio n. Trying n = 0.912: 100 / 0.912 = 109.6 m³/h, where the full-speed curve reads about 45 − 9.6 × 0.3 = 42.1 m; 42.1 × 0.912² = 42.1 × 0.832 = 35.0 m. So about 91 per cent speed, roughly 1,322 rpm on a 1,450 rpm pump.
  • Hydraulic power = 0.02778 × 35 × 1,000 × 9.81 = 9,538 W. At an assumed 72 per cent efficiency, shaft power = 13.25 kW; allowing about 3 per cent for drive losses, 13.65 kW.
  • Saving = 17.52 − 13.65 = 3.87 kW. Over 6,000 hours that is about 23,200 kWh, or roughly ₹1.86 lakh a year at ₹8 per kWh (illustrative).

Note that the speed only fell to 91 per cent, not to 100 / 116 = 86 per cent, because the 20 m of static head does not shrink with flow. Systems with high static head save less from speed control than the simple cube law suggests.

Keep in the pump file Source
Curve for the actual speed and impeller diameter Supplier, with serial number
Design duty point and BEP flow Datasheet
Measured duty point, with date Flow meter and pressure gauges
NPSH available calculation Plant engineering
Motor rating and running current Nameplate and site reading

Checklist when a pump’s flow changes

  • Suction and discharge pressures measured and converted to head
  • Duty point plotted on the correct curve
  • Valve positions and filter condition checked
  • Point compared with the 70 to 120 per cent of BEP window

Frequently asked questions

What is the best efficiency point?

The flow at which the pump is most efficient. Shock and recirculation losses are lowest there, and loads on the shaft and bearings are smallest.

Why does a pump curve fall as flow rises?

Because the impeller can add less energy per unit of liquid at higher flow, and internal losses rise.

Can I use the same curve for different liquids?

Head versus flow stays the same for water-like liquids of different density, but power and pressure change with density. Viscous liquids need corrections.

What does trimming an impeller do?

It lowers head and flow for a given speed. Approximate effects follow the affinity laws for diameter, and the manufacturer’s curves show the trimmed values.

Related guides: Pump Overheating at Low Flow: Minimum Flow Explained With Numbers and Pump Vibration: Telling Cavitation, Misalignment and Bearing Wear Apart. This guide is part of our pumps pillar guide.

Further reading: Hydraulic Institute (pump standards and user guidance).

General guidance. Final pump selection should use the manufacturer’s certified curves.

Sources and further reading

For standards, data and independent guidance on this topic, see US Department of Energy pump systems resources (pump efficiency guidance), American Petroleum Institute (pump and seal standards) and The Engineering ToolBox (engineering reference data and calculators). Always check the current edition and your site conditions before applying any figure.

Free tool for this topic

Pump Power & Motor Size CalculatorHydraulic power, shaft power and recommended motor rating for centrifugal pumps from flow, head, density and efficiency.
Open calculator

Continue learning

More on Pumps, Valves and Piping

View all →
Sponsored
Jignesh S Panchal
Technical Editorial Author Verified Editor

Jignesh S Panchal

Founder — Jaadu Digital & Musafir Infotech · 9+ Years in Industrial B2B

Jignesh S Panchal is the founder of Jaadu Digital and Musafir Infotech, and the publisher behind EngiTech. With over 9 years of hands-on experience in industrial marketing and B2B growth, he works closely with machinery OEMs, process equipment manufacturers, and industrial service providers across thermal processing, fluid handling, automation, packaging, and plant reliability. Combining deep practical knowledge of industrial manufacturing with how technical buyers actually evaluate equipment, he built EngiTech to give plant engineers and procurement teams reliable sizing tools, fault diagnostics, and verified B2B supplier discovery.

Your saved guides

Saved only in this browser. No account required.

Advertisement