New in the library Presented by Jaadu Digital ↗
Free tools

O-Ring & Seal Chemical Compatibility Chart (Viton, EPDM, NBR, PTFE, FFKM)

Industrial O-ring chemical compatibility chart for Viton (FKM), EPDM, NBR, PTFE, FFKM & Silicone across 30 plant fluids, temp limits & mechanical seal guide.

Showing 30 of 30 industrial fluids

Rating Key: A Excellent   B Good (minor swell)   C Limited / Static only   X Not Recommended

Industrial Fluid / Chemical Viton (FKM)
-20..+200°C
EPDM
-40..+150°C
NBR
-30..+100°C
PTFE
-200..+260°C
FFKM
-15..+315°C
Silicone
-55..+200°C
Field Guidance
Steam (Saturated <= 180 deg C) X A X A A C Steam hydrolyzes Viton & NBR; use peroxide-cured EPDM or PTFE/FFKM
Sulfuric Acid (98% Conc.) A X X A A X FKM (Type B/F) or PTFE/FFKM required for conc. H2SO4
Sulfuric Acid (Dilute 10-30%) A A C A A B EPDM & FKM perform well at ambient temp
Hydrochloric Acid (37% HCl) A B X A A X FKM, PTFE or FFKM preferred; avoid NBR/Silicone
Sodium Hydroxide (NaOH Caustic 50%) C A B A A C EPDM is top elastomer choice for hot caustic CIP
Nitric Acid (50%) B X X A A X Strong oxidizer; use PTFE, FFKM, or Viton GF
Hydraulic Oil (Mineral ISO VG 46) A X A A A B EPDM swells severely in mineral oil; use NBR or FKM
Diesel Fuel / Kerosene A X A A A X NBR or FKM standard for fuel transfer pumps
Acetone X A X A A B Ketones destroy FKM & NBR; use EPDM, PTFE, or FFKM
MEK (Methyl Ethyl Ketone) X A X A A C Use EPDM, PTFE, or FFKM; never Viton
Ammonia (Anhydrous / Aqueous) X A B A A C Ammonia attacks FKM; EPDM or PTFE recommended
Water / Ethylene Glycol Coolant A A A A A A EPDM best above 100 deg C; NBR fine <= 95 deg C
CIP Cleaners (Alkaline / Acid Cycle) B A C A A B EPDM or PTFE handles hot alternating caustic/acid CIP
Sodium Hypochlorite (12% Bleach) A B X A A B FKM or PTFE/FFKM best for concentrated bleach
Phosphoric Acid (85%) A A X A A B FKM or EPDM both resist phosphoric acid well
Toluene / Xylene (Aromatics) A X X A A X FKM, PTFE, or FFKM mandatory for aromatic solvents
Methanol C A A A A A Standard FKM swells in methanol; use EPDM, NBR, or FKM-GF
Ethanol (95% / Process Alcohol) A A B A A A EPDM & FKM both widely used in alcohol service
Acetic Acid (Glacial) C A X A A B EPDM, PTFE, or FFKM preferred over standard Viton
Seawater / Brine (NaCl) A A A A A A All major elastomers compatible; watch temp & abrasion
Compressed Air (With Oil Mist) A X A A A B Oil carryover attacks EPDM; use NBR or FKM
Silicone Oil / Greases A A A A A X Silicone oil swells silicone rubber; use NBR/EPDM/FKM
Vegetable / Food Grade Oil A X A A A B FDA NBR, FKM, or PTFE for edible oils
Skydrol (Phosphate Ester Hydraulic) X A X A A C EPDM or PTFE is standard for Skydrol systems
Chlorine Gas (Wet) A C X A A X Use PTFE, FFKM, or specialty FKM-GF
Ozone (Ozonated Water / Air) A A X A A A NBR cracks rapidly under ozone; use EPDM, FKM, or PTFE
Hydrogen Peroxide (30%) A B X A A B FKM, PTFE, or FFKM for peroxide dosing pumps
Methylene Chloride (DCM) B X X A A X PTFE or FFKM strongly preferred for chlorinated solvents
Boiler Feedwater (Amine Treated) X A C A A X Boiler amines attack FKM; use EPDM or PTFE/FFKM
Natural Gas / LPG / Propane A X A A A C NBR or FKM standard for gas & LPG seals

Elastomer Temperature Limits & Mechanical Seal Selection Guide

  • Viton (FKM, -20°C to +200°C / -4°F to +392°F): Default for mineral oils, fuels, aromatics, and mineral acids. Avoid steam, hot water > 100°C, amines, and ketones.
  • EPDM (-40°C to +150°C / -40°F to +302°F): Best for steam, hot water, caustic CIP (NaOH), and ketones. Never use in mineral oil or diesel.
  • NBR / Buna-N (-30°C to +100°C / -22°F to +212°F): Economical for hydraulic oil, air mist, brine, and diesel; cracks under ozone or strong acids.
  • PTFE (-200°C to +260°C) & FFKM (-15°C to +315°C): Pair with Silicon Carbide (SiC/SiC) or Carbon/SiC mechanical seal faces for corrosive chemical pumps and high-temperature reactors.
Live Interactive Calculator · SI Metric & US Imperial

Pipe Pressure Drop Calculator (Darcy–Weisbach)

Velocity, Reynolds number, friction factor and pressure drop for liquids and gases in pipes, including fittings.

Free engineering tool
Formula, worked example and FAQs below · results update as you type

3" Sch 40 = 77.9 mm ID

mm

kg/m³

cP (mPa·s)

ΣK

90° elbow 0.75 · gate valve 0.2 · globe valve 10 · tee branch 1.0 · exit 1.0



Results

Velocity
—

Reynolds number
—
Re

Darcy friction factor
—
f

Total pressure drop
—

of which pipe friction
—
kPa

of which fittings
—
kPa

Head loss
—

Results are engineering estimates for preliminary design. Verify critical values with codes, vendor data or a qualified engineer.

Advertisement

Embed this free tool on your website or blog

Free to embed on engineering blogs, university guides, and plant wikis (zero login required).

Frequently Asked Questions

Why should Viton (FKM) O-rings never be used in steam or acetone service?

Hot steam (> 100°C) hydrolyzes standard FKM polymers causing hardening and cracking, while ketones like acetone and MEK cause rapid severe swelling. Use peroxide-cured EPDM, PTFE, or FFKM for steam and ketones.

Can EPDM O-rings be used with mineral hydraulic oil or diesel fuel?

No. EPDM swells and degrades rapidly in petroleum hydrocarbons, mineral oils, and fuels. Always specify NBR (Buna-N) up to 100°C or Viton (FKM) up to 200°C for oil and fuel pumps.

When is FFKM (Kalrez) or PTFE justified over Viton or EPDM?

Specify PTFE or FFKM when seals face alternating mixed acids, chlorinated solvents, aromatic hydrocarbons, and caustic CIP above 200°C where standard elastomers swell or embrittle.

Your saved guides

Saved only in this browser. No account required.

Advertisement