# Orifice Plate & Venturi DP Flow Calculator

> Calculate volumetric flow, mass flow, beta ratio \(d/D\) and permanent pressure loss across a concentric orifice plate or Venturi tube per ISO 5167.

Canonical: https://engitech.in/orifice-plate-venturi-flow-calculator/ | Published: 2026-11-18 | Updated: 2026-11-18

Calculate volumetric flow, mass flow, beta ratio (d/D) and permanent pressure loss across a concentric orifice plate or Venturi tube per ISO 5167.

Free engineering tool Formula, worked example and FAQs below · results update as you type

Results

**Volumetric flow**

—

**Mass flow**

—

**Beta ratio (β = d / D)**

—

**Permanent pressure loss**

—

Results are engineering estimates for preliminary design. Verify critical values with codes, vendor data or a qualified engineer.

## Formula used

ISO 5167 incompressible flow: **Q** = (Cd × Ao ÷ √(1 − β⁴)) × √(2·ΔP ÷ ρ), where β = d ÷ D and Ao = π·d² ÷ 4.

Mass flow **ṁ** = Q × ρ. Keep β between 0.20 and 0.75 for reliable ISO 5167 accuracy.

## How to use this calculator

1. Enter pipe inside diameter D and orifice bore d.
2. Enter the differential pressure ΔP read by the DP transmitter.
3. Enter operating fluid density and discharge coefficient (0.61 for sharp-edged orifice, 0.98 for Venturi).
4. Verify β lies between 0.20 and 0.75 and check permanent pressure loss against pump head.

## Worked example

Water (1000 kg/m³) through a 60 mm orifice in a 100 mm bore pipe (β = 0.60, Cd = 0.61) at ΔP = 25 kPa gives **46.8 m³/h** (13.0 kg/s) with **16.2 kPa** permanent pressure loss.

## Frequently asked questions

**Why is flow proportional to the square root of ΔP?**

Differential pressure varies with kinetic energy (½ρv²), so doubling the flow quadruples ΔP. DP transmitters apply square-root extraction to output a linear 4–20 mA flow signal.

**When is a Venturi tube better than an orifice plate?**

Venturi tubes recover 85–90 % of the differential pressure (far lower permanent energy loss) and resist plugging on slurries or large cooling-water headers.

**How much straight pipe run does an orifice plate need?**

Depending on β and upstream fittings, ISO 5167 typically requires 10–40 pipe diameters of straight run upstream and 4–7 diameters downstream.

## More free engineering tools

[**Pump Power & Motor Size Calculator**Hydraulic power, shaft power and recommended motor rating for centrifugal pumps from flow, head, density and efficiency.](https://engitech.in/pump-power-calculator/)[**Fan & Blower Power Calculator with Fan Laws**Air power, shaft power and motor size for centrifugal fans and blowers, plus fan-law results for a new speed.](https://engitech.in/fan-blower-power-calculator/)[**Pipe Pressure Drop Calculator (Darcy–Weisbach)**Velocity, Reynolds number, friction factor and pressure drop for liquids and gases in pipes, including fittings.](https://engitech.in/pipe-pressure-drop-calculator/)[**Pump NPSH Available Calculator**Net positive suction head available (NPSHa) for a pump, compared with the pump’s NPSHr to check cavitation margin.](https://engitech.in/npsh-calculator/)[**Pipe Flow Velocity & Reynolds Number Calculator**Flow velocity, Reynolds number and flow regime for a liquid or gas in a pipe, plus the pipe bore needed for a target velocity.](https://engitech.in/pipe-velocity-reynolds-calculator/)[**Pump Affinity Laws Calculator (Speed & Impeller Trim)**New flow, head and power of a centrifugal pump after a change in speed or impeller diameter, using the affinity laws.](https://engitech.in/pump-affinity-laws-calculator/)