# Cyclone Dust Collector Cut-Size \(d50\) & Velocity Calculator

> Calculate Stairmand high-efficiency cyclone inlet velocity, Lapple 50 % cut-point particle diameter \(d50 in µm\) and estimated gas pressure drop.

Canonical: https://engitech.in/cyclone-dust-collector-cut-size-calculator/ | Published: 2026-11-18 | Updated: 2026-11-18

Calculate Stairmand high-efficiency cyclone inlet velocity, Lapple 50 % cut-point particle diameter (d50 in µm) and estimated gas pressure drop.

Free engineering tool Formula, worked example and FAQs below · results update as you type

Results

**Inlet velocity**

—

**Cut-point diameter (d50)**

—

**Estimated pressure drop**

—

Results are engineering estimates for preliminary design. Verify critical values with codes, vendor data or a qualified engineer.

## Formula used

Stairmand high-efficiency proportions: inlet area a × b = (0.5 Dc) × (0.2 Dc) = 0.1 Dc², effective turns Ne = 5.

Lapple cut-size: **d50** = √(9·μ·b ÷ (2·π·Ne·vin·(ρp − ρg))). Pressure drop **ΔP** ≈ 6.4 × ½·ρg·vin².

## How to use this calculator

1. Enter actual gas volumetric flow at operating temperature and pressure.
2. Enter cyclone cylinder body diameter Dc.
3. Enter gas viscosity, gas density and particle density.
4. Aim for 15–22 m/s inlet velocity; follow with a <a href="/bag-filter-sizing-calculator/">Bag Filter</a> for sub-5 µm emissions compliance.

## Worked example

At 5,000 Am³/h in an 800 mm Stairmand cyclone (2500 kg/m³ dust, air at 20 °C), inlet velocity is **21.7 m/s**, cut-size **d50 ≈ 4.3 µm** and pressure loss ≈ **1,808 Pa (184 mmH2O)**.

## Frequently asked questions

**What does a cyclone d50 cut-size of 5 µm mean?**

Particles of 5 µm aerodynamic size have a 50 % chance of being collected; larger particles are captured at progressively higher efficiency (80–99 %), while finer sub-micron dust passes out the vortex finder.

**Why do multi-cyclone banks perform better than one giant cyclone?**

Splitting flow across smaller-diameter cyclones increases centrifugal acceleration (v²/r) at the same inlet velocity, lowering d50.

**What happens if cyclone inlet velocity is too high (> 26 m/s)?**

Pressure drop climbs with v², abrasive wear accelerates rapidly on the volute and cone, and particle re-entrainment from the wall can reduce collection efficiency.

## More free engineering tools

[**Compressed Air Leak Cost Calculator**Air lost, compressor power wasted and annual energy cost of compressed-air leaks by hole size and pressure.](https://engitech.in/compressed-air-leak-cost-calculator/)[**Bag Filter (Dust Collector) Sizing Calculator**Filter cloth area, number of bags and can velocity check for pulse-jet and reverse-air bag filters from gas flow and air-to-cloth ratio.](https://engitech.in/bag-filter-sizing-calculator/)[**Compressed Air Receiver Size Calculator**Receiver tank volume needed to cover a short peak demand above compressor capacity without pressure falling below the minimum.](https://engitech.in/air-receiver-size-calculator/)[**Motor Torque, Power & Current Calculator**Convert motor power and speed to shaft torque, or torque to power, and estimate full-load current for three-phase and single-phase motors.](https://engitech.in/motor-torque-power-calculator/)[**CNC Feeds & Speeds Calculator**Spindle speed, feed rate, metal removal rate and cutting power for milling, drilling and turning with carbide tools.](https://engitech.in/cnc-feeds-speeds-calculator/)[**Beam Deflection & Bending Stress Calculator**Maximum deflection, bending moment and stress for simply supported, cantilever and fixed beams with common steel sections.](https://engitech.in/beam-deflection-calculator/)

[All calculators →](https://engitech.in/engineering-tools/)